Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Chen,J.  Bai,L.Y.  Zhang,L.  Hu,M.  Zhang,Y.P.    
Article title: Novel Liquid-Liquid-Solid Microextraction Using Molecularly Imprinted Polymer Monolithic Fibres and Its Application to the Extraction of s-Triazine Herbicides from Water Samples
Publication date: 2014
Journal : Adsorption Science & Technology
Volume: 32
Issue: (4)
Page numbers: (331-342)
DOI: 10.1260/0263-6174.32.4.331
Alternative URL: http://journals.sagepub.com/doi/abs/10.1260/0263-6174.32.4.331

Abstract: A novel method to quickly prepare molecularly imprinted polymer (MIP) monolithic fibres is developed using microwave irradiation. The well-known water-compatibility problem of MIP is overcome by liquid-liquid-solid microextraction (LLSME). The atrazine (ATR) MIP fibre was obtained after silica was etched away with a controlled length of 1 cm, and subsequently characterized by scanning electron microscopy. Main factors affecting the selective extraction, including extraction time, desorption time, extraction and desorption solvents, were investigated for LLSME procedures in detail. The selectivity was also evaluated using the ATR template molecule and its structurally related compounds, including 2-amino-4-methoxy-6-methyl-1,3,5-triazine, terbuthylazine, ametryn and metribuzin pesticides. The extraction ratio of target pesticides in ATR-imprinted polymeric monolithic fibre was increased to more than 10 times than that in non-imprinted polymeric monolithic fibre. The resultant fibres coupled by HPLC were successfully applied to detect ATR and its analogue pesticides with recoveries in the range of 68.3-92.6%. In addition, the LLSME technique was proved to be effective in extracting spiked TRI, ATR, AME and TER in lake water. This method provided a satisfactory solution for the simple, rapid, selective and sensitive pre-treatment of trace herbicides in various aqueous samples. The results demonstrate that the proposed technique could solve the water compatibility problem when the MIP monolithic fibre was exposed directly to a non-polar solvent above the aqueous solution
Template and target information:   atrazine; ATR




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website