Authors:   Ahari,H.  Razavilar,V.  Akbari Adreghani,B.  Motallebi Moghanjoghi,A.A.    
Article title: Nanobiosensor designing with molecular framework polymer method compared with agent-linked nanosilica biosensor for Staphylococcus aureus exotoxin detection
Publication date: 2014
Journal : Iranian Journal of Fisheries Sciences
Volume: 13
Issue: (3)
Page numbers: (667-683)
Alternative URL: http://www.jifro.ir/files/site1/user_files_eb12be/ahari_h-A-10-413-2-7d97a16.pdf

Abstract: Considering the ever increasing population and industrialization leading to developmental trend of humankind's life, we are hardly able to detect the toxins produced in food products using traditional techniques. In this technique, the production of molecular framework and polymer is done using meta acrylic acid monomers, which are formed via covalence connection between meta acrylic acid monomers (MAA) of white polymer. Here also hydrogenised connection between exotoxin amino acid and meta acrylic acid is made that would function as the selective absorption for that. Then in the second stage, based on the bacterial antibody connection to nanoparticle, a sensor was used. In this part of the research, as the basis for absorption for the recognition of bacterial toxin, medium sized silica nanoparticles of 10 nanometer in the form of solid powder were utilized with Notrino brand. Then the suspension produced from agent-linked nanosilica which was connected to bacterial antibody was positioned near the samples of distilled water, that were contaminated with Staphylococcus aureus bacterial toxin with the density of 10-3 , so that in case any toxin exists in the sample, a connection between toxin antigen and antibody would be formed. Finally, the light absorption related to the connection of antigen to the particle attached antibody was measured using spectrophotometers. The results indicate that the molecular framework polymer sensor is capable of detecting up to the density of 10-3, but not lower than that, whereas using the second sensor, up to 10-4 of density is detectable. Additionally, the sensitivity of the sensors were examined after 60 days and the first sensor by the day of 28 and the second sensor by the 56 day had confirmatory results and started to decrease after those time periods.
Template and target information:   Staphylococcus aureus toxin
Author-assigned keywords: Nanobiosensor; Staphylococcus aureus; Exotoxin; Molecular Framework Polymer Nanosensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website