Mipdatabase live, currently comprising 19367 items



Reference Type: Book Chapter
Authors:   Zia,A.I.  Rao,A.  Mukhopadhyay,S.C.    
Chapter title: Molecularly Imprinted Impedimetric Sensing of Phthalates: A Real-Time Assay Technique
Publication date: 2016
Chapter number: 3
Page numbers: (55-79)
DOI: 10.1007/978-3-319-21671-3_3

Book Title: Next Generation Sensors and Systems
Editors: Mukhopadhyay,S.C.
Series title: Smart Sensors, Measurement and Instrumentation
Volume: 16
Publisher: Springer
ISBN: 978-3-319-21670-6

Abstract: Phthalates are the most ubiquitous chemicals that are used as plasticizer in almost every plastic product manufacturing including food packaging, toys, and pharmaceutical consumables. The carcinogenic and teratogenic nature of these synthetic chemicals has been well cited in published research as a potential health threat for all living beings on earth. Contemporary phthalates detection techniques require high level of skills, expensive equipment and extended analysis time as compared to the rapid assay method presented in this chapter. A real-time, non-invasive detection of phthalates was performed by employing electrochemical impedance spectroscopy technique incorporating an enhanced penetration depth interdigital capacitive transducer. A research was conducted to investigate the application of pre-concentration extraction polymer with molecular imprinted recognition sites as an analyte sensitive coating for the sensor to introduce molecular selectivity for di (2-ethylhexyl) phthalate molecules. Self-assembled monolayer with embedded imprinted polymer was used to functionalize the sensing surface in order to capture phthalate molecules spiked in the water samples and commercial drinks. Equilibrium rebinding experiments were conducted to demonstrate the adsorption capabilities of the molecular imprinted polymer coating. Impedance spectra were obtained over a frequency range by applying frequency response analyzer (FRA) algorithm to observe impedance change that occurred for various concentrations of the analyte. Complex nonlinear least square (CNLS) curve fitting spectrum algorithm interpreted the experimentally obtained impedance spectra into electrochemical equivalent electric circuit and corresponding parameters. Analysis of the equivalent circuit was used to explain the kinetics of chemical bindings taking place at the electrode-electrolyte interface in the electrochemical cell in terms of electrical component parameters. The results from the proposed detection system were validated by high-performance liquid chromatography (HPLC-DAD)
Template and target information:   phthalates; di(2-ethylhexyl) phthalate




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website