Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Ertürk,G.  Özen,H.  Tümer,M.A.  Mattiasson,B.  Denizli,A.    
Article title: Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples
Publication date: 2016
Journal : Sensors and Actuators B: Chemical
Volume: 224
Page numbers: (823-832)
DOI: 10.1016/j.snb.2015.10.093
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0925400515305591

Abstract: Prostate specific antigen (PSA) is an important biomarker for diagnosis and prognosis of prostate cancer. Herein, microcontact PSA-imprinted surface plasmon resonance (SPR) sensor chip was developed for sensitive, real-time detection of PSA. The imprinted chip was prepared in the presence of methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker via UV polymerization using microcontact imprinting technique. PSA imprinted SPR sensor chip was characterized by atomic force microscope (AFM), scanning electron microscope (SEM), ellipsometry, dispersive Raman and Fourier transform infrared spectroscopy (FT-IR). Under optimal conditions, PSA detection was performed with standard PSA solutions in the concentration range of 0.1-50 ng mL-1 with a detection limit (LOD) of approximately 91 pg mL-1 (18 × 10-14 M). Selectivity studies were performed against human serum albumin (HSA) and lysozyme (Lyz) as the competitive agents. The developed system was evaluated for analysis of 10 clinical serum samples and showed approximately 98% agreement between the results obtained by commercial enzyme-linked immunosorbent assay (ELISA) method without significant differences at the 0.05 significance level (p = 0.751, p > 0.05)
Template and target information:   protein; prostate specific antigen; PSA; biomarker
Author-assigned keywords: Prostate Specific Antigen; surface plasmon resonance; Microcontact imprinting; enzyme-linked immunosorbent assay




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website