Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Sánchez-González,J.  Barreiro-Grille,T.  Cabarcos,P.  Tabernero,M.J.  Bermejo-Barrera,P.  Moreda-Piñeiro,A.    
Article title: Magnetic molecularly imprinted polymer based - micro-solid phase extraction of cocaine and metabolites in plasma followed by high performance liquid chromatography - tandem mass spectrometry
Publication date: 2016
Journal : Microchemical Journal
Volume: 127
Page numbers: (206-212)
DOI: 10.1016/j.microc.2016.03.014
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0026265X16300121

Abstract: A novel adsorbent, magnetic molecularly imprinted polymer (MMIP) based on magnetite nanoparticles surface-covered with an MIP selective for cocaine (COC), was synthesised and used in batch micro-solid phase extraction (μ-SPE) for isolation of COC and metabolites (benzoylecgonine, BZE; cocaethylene, CE; and ecgonine methyl ester, EME) from plasma samples. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used for performing analysis. Parameters such as sample pH, magnetic stirring speed, extraction temperature and time (loading stage), composition and volume of the eluting solution, and desorption time, were optimised. Under the most favourable conditions, the highest extraction yields were obtained by using 0.1 to 1.0 mL of plasma (pH adjusted at 8.5) plus 50 mg of MMIP, and magnetic stirring (20 °C, 100 rpm) for 4 min. Elution was performed with 2 mL of a dichloromethane/2-propanol/ammonium hydroxide (75:20:5) mixture under ultrasound irradiation (325 W, 35 kHz) for 5 min. The limits of detection were between 0.013 and 0.36 ng L-1, and the limits of quantification were from 0.043 to 1.2 ng L-1. The relative standard deviations of intra- and inter-day tests (three concentration levels tested) ranged from 1 to 9% and from 2 to 10%, respectively. Analytical recoveries were in the range of 91-102% when spiking drug-free plasma samples at three concentration levels. Accurate results were also obtained after analysing a BTMF 1/11-B control material
Template and target information:   cocaine; COC; benzoylecgonine; BZE; cocaethylene; CE; ecgonine methyl ester; EME
Author-assigned keywords: Magnetic molecularly imprinted polymer; plasma; Cocaine; HPLC-MS; MS




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website