Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Qi,Y.X.  Li,G.Y.  Wei,C.L.  Zhao,L.J.  Gong,B.L.    
Article title: Preparation of Magnetic Molecularly Imprinted Polymer for Melamine and its Application in Milk Sample Analysis by HPLC
Publication date: 2016
Journal : Journal of Biomedical Sciences
Volume: 5
Issue: (2)
Article number: 15
Alternative URL: http://www.jbiomeds.com/abstract/preparation-of-magnetic-molecularly-imprinted-polymer-for-melamine-and-its-application-in-milk-sample-analysis-by-hplc-9099.html

Abstract: In this work, a simple and selective method was successfully developed for the determination of melamine (MEL) in milk sample using magnetic surface molecularly imprinted polymer (MMIPs) as sorbent. The MMIPs has been prepared by using MEL as template molecule, methacrylic acid (MAA) as functional monomer and Fe3O4@SiO2 as magnetic support. The polymer was characterized by means of fourier transform infrared(FT-IR) analysis, X-ray diffraction (XRD) analysis, thermogravimetric Analysis (TGA), scanning electron microscope(SEM) and vibrating sample magnetometer (VSM). The results demonstrated that an imprinted polymer layer was successfully coated onto the surface of modified Fe3O4 nanomaterials, resulting in a good magnetic responsibility. The UV spectrophotometry was used to demonstrate the interaction between MEL and MAA. It was found that one MEL was entrapped by two MAA molecules. Binding selectivity, adsorption capacity and the reusability for MMIPs were also evaluated in details. Results indicated the prepared MMIPs exhibited high adsorption capacity, fast binding ability and high selectivity for melamine. Detection limits for melamine were within the range of 0.15-3.00 μg/mL, which could meet the analysis of trace melamine in milk. Calibration curve was established with R of 0.9997. The limit of detection (LOD) of this new method was 15 μg/L. The obtained results revealed that the extraction recoveries of melamine from real samples were in the range of 85.6% to 104.2%. This work proposed a sensitive, rapid, reliable and convenient approach for the determination of trace melamine in complicated milk sample.
Template and target information:   melamine; MEL
Author-assigned keywords: Melamine; Magnetic molecularly imprinted polymer; Fe3O4@ SiO2; ecognition character; PLC




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website