Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Khalilian,F.  Kermani,F.K.    
Article title: Selective Dispersive Solid Phase Extraction of Sertraline Using Surface Molecularly Imprinted Polymer Grafted on SiO2/Graphene Oxide
Publication date: 2017
Journal : Journal of Chemical Health Risks
Volume: 7
Issue: (1)
Page numbers: (49-60)
Alternative URL: http://www.jchr.org/index.php/JCHR/article/download/724/590

Abstract: A surface molecularly imprinted dispersive solid phase extraction coupled with liquid chromatography-ultraviolet detection is proposed as a selective and fast clean-up technique for the determination of sertraline in biological sample. Surface sertraline-molecular imprinted polymer was grafted and synthesized on the SiO2/graphene oxide surface. Firstly SiO2 was coated on synthesized graphene oxide sheet using sol-gel technique. Prior to polymerization, the vinyl group was incorporated on to the surface of SiO2/graphene oxide to direct selective polymerization on the surface. Methacrylic acid, ethylene glycol dimethacrylate and ethanol were used as monomer, cross-linker and progen, respectively. Non-imprinted polymer was also prepared for comparing purposes. The properties of the molecular imprinted polymer were characterized using field emission-scanning electron microscopy and Fourier transform infrared spectroscopy methods. The surface molecular imprinted polymer was utilized as an adsorbent of dispersive solid phase extraction for separation and preconcentration of sertraline. The effects of the different parameters influencing the extraction efficiency, such as sample pH were investigated and optimized. The specificity of the molecular imprinted polymer over the non-imprinted polymer was examined in absence and presence of competitive drugs. Sertraline calibration curve showed linearity in the ranges 1-500 μg L-1. The limits of detection and quantification under optimized conditions were obtained 0.2 and 0.5 μg L-1. The within-day and between-day relative standard deviations (n=3) were 4.3 and 7.1%, respectively. Furthermore, the relative recoveries for spiked biological samples were above 92%.
Template and target information:   sertraline
Author-assigned keywords: Biological liquids analysis; Sertraline; Dispersive Solid Phase Extraction; SiO2; graphene oxide; Surface molecular imprinted polymer




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website