Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Braga,G.S.  Lieberzeit,P.A.  Fonseca,F.J.    
Article title: Molecularly Imprinted Polymer Based Sensor to Detect Isoborneol in Aqueous Samples
Publication date: 2016
Journal : Procedia Engineering
Volume: 168
Page numbers: (448-451)
DOI: 10.1016/j.proeng.2016.11.542
Alternative URL: http://www.sciencedirect.com/science/article/pii/S1877705816338668

Abstract: Herein we report the development of a selective chemical sensor based on molecularly imprinted polymers (MIP) and quartz crystal microbalance (QCM) to detect isoborneol (ISO) in aqueous samples. Their response scales linearly with isoborneol concentration and exhibits sensitivity of -16.23 Hz mM-1 cm-2 at the active area, with a gradient of -25 Hz mM-1. Moreover, they respond rapidly, reversibly and reproducibly. Sensor layers are stable within a period of four weeks during use as compared to a few days for natural receptors. Moreover, ISO-MIP sensor calculated theoretical detection limit is 0.58 mM
Template and target information:   isoborneol
Author-assigned keywords: molecularly imprinted polymer; quartz crystal microbalance; isoborneol; aqueous samples; methacrylic acid




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website