Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Golabi,M.  Kuralay,F.  Jager,E.W.H.  Beni,V.  Turner,A.P.F.    
Article title: Electrochemical bacterial detection using poly(3-aminophenylboronic acid)-based imprinted polymer
Publication date: 2017
Journal : Biosensors and Bioelectronics
Volume: 93
Page numbers: (87-93)
DOI: 10.1016/j.bios.2016.09.088
Alternative URL: http://www.sciencedirect.com/science/article/pii/S0956566316309733

Abstract: Biosensors can deliver the rapid bacterial detection that is needed in many fields including food safety, clinical diagnostics, biosafety and biosecurity. Whole-cell imprinted polymers have the potential to be applied as recognition elements in biosensors for selective bacterial detection. In this paper, we report on the use of 3-aminophenylboronic acid (3-APBA) for the electrochemical fabrication of a cell-imprinted polymer (CIP). The use of a monomer bearing a boronic acid group, with its ability to specifically interact with cis-diol, allowed the formation of a polymeric network presenting both morphological and chemical recognition abilities. A particularly beneficial feature of the proposed approach is the reversibility of the cis-diol-boronic group complex, which facilitates easy release of the captured bacterial cells and subsequent regeneration of the CIP. Staphylococcus epidermidis was used as the model target bacteria for the CIP and electrochemical impedance spectroscopy (EIS) was explored for the label-free detection of the target bacteria. The modified electrodes showed a linear response over the range of 10^3-10^7 cfu/mL. A selectivity study also showed that the CIP could discriminate its target from non-target bacteria having similar shape. The CIPs had high affinity and specificity for bacterial detection and provided a switchable interface for easy removal of bacterial cell
Template and target information:   bacteria; Staphylococcus epidermidis
Author-assigned keywords: 3-aminophenylboronic acid; Whole-cell imprinted polymers; electrochemical impedance spectroscopy; label-free detection; Staphylococcus epidermidis




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website