Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zhao,H.Q.  Jiang,M.Y.  Feng,Y.Y.  Wu,A.L.  Zhan,X.Z.  Deng,J.    
Article title: Aluminum Doped Surface Imprinted Polymer Modified Electrode for Determination of Ronidazole Residue in Food
Publication date: 2016
Journal : Journal of Instrumental Analysis
Volume: 35
Issue: (8)
Page numbers: (993-998)
Alternative URL: http://fxcsxb.com/ch/reader/view_abstract.aspx?file_no=20160811&flag=1

Abstract: An electrochemical sensor for the determination of ronidazole (RNZ) was developed based on a magnetic glassy carbon electrode modified with Al(III) doped core-shell magnetic surface molecularly imprinted polymer (MMIP), which was prepared via the sol-gel method using RNZ as template, 3-aminopropyltriethoxysilane as functional monomer, orthosilicate as cross-linker, and Al3+ as dopant to generate Lewis acid sites in the silica matrix for the metal coordinate interactions with the template RNZ. The component, morphology of MMIP and the performance of the as prepared sensor were characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, powder X-ray diffraction and the electrochemical methods. Various factors affecting the response behavior of the sensor were studied and optimized. Because of the aluminum doping, the imprinted sensor exhibits the best recognition ability and affinity for RNZ in comparison with the aluminum free MMIP and the non-imprinted one. Under the optimal experimental conditions, the peak currents by differential pulse stripping voltammetry were found to vary linearly with RNZ concentrations in the range of 0.05-50.0 μmol/L with a detection limit of 0.015 μmol/L. This sensor was successfully employed to detect RNZ in milk powder and egg samples with recoveries of 88.6%-97.0% and relative standard deviations of 2.9%-4.6%.
Template and target information:   ronidazole; RNZ
Author-assigned keywords: ronidazole (RNZ); magnetic surface molecularly imprinted polymer; differential pulse stripping voltammetry; aluminum doping




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website