Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Borges,M.C.M.  de Oliveira,H.L.  Borges,K.B.    
Article title: Molecularly imprinted solid-phase extraction coupled with LC-APCI-MS-MS for the selective determination of serum cholesterol
Publication date: 2017
Journal : Electrophoresis
Volume: 38
Issue: (17)
Page numbers: (2150-2159)
DOI: 10.1002/elps.201600489

Abstract: The assessment of selective molecularly imprinted solid-phase extraction (MISPE) for clean-up and extraction of cholesterol (CHO) from bovine and human serum samples was evaluated. Two molecular imprinted polymers (MIP) based on organic and inorganic/organic (hybrid) materials were obtained and compared regarding recovery and selectivity toward CHO. Optimum chromatographic separation between the CHO and its isobaric compound lathosterol (LATHO) has been achieved within 15 min using an Agilent Poroshell 120 EC-C18 column (120 mm x 3.0 mm, 2.7 μM) and mobile phase consisting of acetonitrile:methanol (8:2, v/v) at a flow rate of 0.6 mL min-1. Mass spectrometry detection was operated in atmospheric pressure chemical ionization (APCI) (+) mode and the SIM transitions [M - H2O + H]+ for CHO and LATHO were 364.1 ® 161.2 ® 95.2 and 364.1 ® 95.1 ® 81.1 m/z, respectively. The sample preparation could be accomplished within 1 h, and the matrix effect on the MS signal after sample pretreatment did not interfere in the analyses. The method provided a good linear range (0.013-312 μM.) with coefficients of determination of R2 > 0.99, substantial sensitivity (limits of detection of 6.5 nM), good recovery (~90%), high reproducibility (intraday and interday relative standard deviations less than 15%) and satisfactory accuracy (relative error ranged from -13.46% to 11.54%). The organic MIP showed superior performance compared with the hybrid. Finally, the MISPE procedure followed by LC-APCI-MS-MS analysis showed their suitable applicability to examine CHO and LATHO in serum samples
Template and target information:   cholesterol; CHO
Author-assigned keywords: cholesterol; LC-MS-MS; molecularly imprinted polymer; serum




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website