Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Soleimani,E.  Bahrami,A.  Afkhami,A.  Shahna,F.G.    
Article title: Selective determination of mandelic acid in urine using molecularly imprinted polymer in microextraction by packed sorbent
Publication date: 2018
Journal : Archives of Toxicology
Volume: 92
Issue: (1)
Page numbers: (213-222)
DOI: 10.1007/s00204-017-2057-z

Abstract: Mandelic acid (MA) is a major metabolite of ethylbenzene and styrene. For the first time, a selective, fast, and easy-to-use procedure was developed for the determination of MA in urine samples. The new procedure is based on MIMEPS, the combination of a molecularly imprinted polymer (MIP) and microextraction by packed sorbent (MEPS). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used for the separation and determination of MA. The bulk polymerization method was used to synthesize the MIP, and the MIP and non-imprinted polymer (NIP) were characterized by Fourier transform infrared spectroscopy. The selectivity of the MIP was investigated in the presence of interferents. In addition, we investigated the various parameters that affect the performance of the MEPS, including the pH of the sample, the number of extraction cycles, sample volume, and the types and volumes of the washing and elution solvents. A six-point calibration curve was obtained in the range of 0.2-20 μg/mL (R2 = 0.9994). The extraction recovery was more than 88.8%. The limit of detection and the limit of quantitation were 0.06 and 0.2 μg/mL, respectively. The intra- and inter-day precisions were in the range of 3.6-4.7% and 3.8-5.1%, respectively. The accuracy was -8.4 to -11.1%. The optimized procedure was selective, sensitive, and rapid, and it was both user friendly and environmentally friendly. The sample preparation process took only about 5 min, so the MIMEPS-HPLC-UV procedure is recommended as an alternative for the biomonitoring of workers exposed to ethylbenzene and/or styrene
Template and target information:   mandelic acid; MA
Author-assigned keywords: high-performance liquid chromatography; Microextraction by packed sorbent; molecularly imprinted polymer; mandelic acid; Urine sample




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website