Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Díaz-Liñán,M.C.  López-Lorente,A.I.  Cárdenas,S.  Lucena,R.    
Article title: Molecularly imprinted paper-based analytical device obtained by a polymerization-free synthesis
Publication date: 2019
Journal : Sensors and Actuators B: Chemical
Volume: 287
Page numbers: (138-146)
DOI: 10.1016/j.snb.2019.02.048
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0925400519302552

Abstract: In the last years, the imprinting technology has raised attention and different polymers with artificial recognition sites towards a target molecule have been developed. In this article, a polymerization-free method -which only requires the dissolution of nylon-6 polymer and its subsequent incubation with the template molecule- has been employed for the preparation of a molecularly imprinted polymer directly immobilized on filter paper, thus increasing the versatility and manageability of the new material. The molecularly imprinted paper-based analytical device (MIP PAD) has been coupled to a fluorimeter via a custom-built platform, which enables direct measurement of the fluorescence at the surface of the MIP PAD. Extraction efficiency of the MIP PAD was evaluated using quinine as model analyte, measuring the fluorescence directly at the MIP PAD surface after incubation on aqueous standards of quinine and soda drink, showing that the performance of the imprinted material was superior to that of the non-imprinted polymer. In addition, the selectivity of the MIP PAD versus analogous organic fluorescent molecules has been further evaluated using norfloxacin, observing that the molecular imprinting results in selective extraction of quinine. The performance of the method has been evaluated for quantitative analysis, achieving limits of detection (LOD) and quantification (LOQ) for aqueous standards of 0.37 and 1.24 mg L-1, respectively, while in the case of spiked soda drink the LOD and LOQ were 0.63 and 2.11 mg L-1, respectively. The reproducibility of the measurements was also evaluated, observing values within range 2.30 and 9.07% measured as relative standard deviation
Template and target information:   quinine
Author-assigned keywords: molecularly imprinted polymer; nylon-6; microextraction; Cellulose paper; quinine; fluorescence; Paper-based analytical device




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website