Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,S.L.  Geng,Y.L.  Sun,X.W.  Wang,R.Y.  Zheng,Z.J.  Hou,S.H.  Wang,X.  Ji,W.H.    
Article title: Molecularly imprinted polymers prepared from a single cross-linking functional monomer for solid-phase microextraction of estrogens from milk
Publication date: 2020
Journal : Journal of Chromatography A
Volume: 1627
Article number: 461400
DOI: 10.1016/j.chroma.2020.461400
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0021967320306762

Abstract: In this work, a single cross-linking functional monomer, 2,5-divinylterephthalaldehyde, was designed and synthesized to simplify the preparation of molecularly imprinted polymers (MIPs). In the presence of estradiol as a template, MIPs were successfully prepared using 2,5-divinylterephthalaldehyde along with a solvent and initiator. This method reduced most of the complex variables encountered in the traditional synthesis. Characterization of the morphology and structure of the MIPs was performed by scanning electron microscopy, Fourier transform infrared spectroscopy, and Brunauer-Emmett-Teller analysis. Compared with non-imprinted polymers, the MIPs had higher adsorption capacities for five estrogens with imprinting factors above 2.9. The MIPs had high extraction efficiencies, good functional properties, long lifetimes, and good reproducibility, which made them suitable for solid-phase microextraction (SPME). Coupled with ultra-high performance liquid chromatography tandem mass spectrometry, the MIP-based fibers were applied to SPME for the analysis of five estrogens in milk samples. Under the best conditions, the established method had a wide linear range (0.5-10000 ng kg-1), low limits of detection (0.08-0.26 ng kg-1) and quantification (0.26-0.87 ng kg-1), good precision (3.2-8.1%, n = 6), and fiber-to-fiber reproducibility (4.3%-8.8%, n = 3). The MIPs-based fibers can be reused at least 60 times without apparent loss of extraction efficiency. Finally, this method was applied to the determination of target estrogens in milk samples with satisfactory relative recoveries (84.3%-105%, relative standard deviation ≤ 7.8%)
Template and target information:   estradiol; estrogens
Author-assigned keywords: solid-phase microextraction; molecularly imprinted polymer; Estrogens ultra-high performance liquid chromatography tandem mass spectrometry; milk




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website