Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zeng,L.S.  Zhang,X.  Wang,X.  Cheng,D.Q.  Li,R.F.  Han,B.  Wu,M.M.  Zhuang,Z.J.  Ren,A.N.  Zhou,Y.K.  Jing,T.    
Article title: Simultaneous fluorescence determination of bisphenol A and its halogenated analogs based on a molecularly imprinted paper-based analytical device and a segment detection strategy
Publication date: 2021
Journal : Biosensors and Bioelectronics
Volume: 180
Article number: 113106
DOI: 10.1016/j.bios.2021.113106
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0956566321001433

Abstract: Bisphenol A (BPA) and its halogenated analogs tetrabromobisphenol A (TBBPA) and tetrachlorobisphenol A (TCBPA) are common environmental contaminants and a method for their simultaneous determination is urgently needed. A paper-based analytical device (PAD) was prepared using a metal-organic framework of UiO-66-NH2 coated with molecularly imprinted polymers (MIPs) using TBBPA as a template. The maximum adsorption capacity was 120.94 mg g-1 and the imprinting factor was 4.07. The selective recognition ability of this PAD enabled the effective separation of TBBPA, TCBPA and BPA based on paper chromatography. Subsequently, the PAD cut into segments were used individually to determine the presence of target chemicals using a highly sensitive fluorescent method. Under ultraviolet light irradiation, UiO-66-NH2 acts as a photocatalyst to produce reactive oxygen species (ROS) that degrade TBBPA, TCBPA or BPA in the imprinted cavities and the fluorescent signal of 2',7'-dichlorodihydrofluorescein diacetate (H2DCFDA) added as a ROS probe enabled the indirect determination of target chemicals. This method could determine BPA and its halogenated analogs in dust samples simultaneously with detection limits ranging from 0.14 to 0.30 ng g-1. The intraday relative standard deviation (RSD) was ≤ 6.8% and interday RSD was ≤ 8.1%. The recoveries ranged from 91.0 to 105.6% with RSD values that were ≤ 7.5%. The results stemmed from this method were consistent with those obtained from LC-MS/MS. It is an environmentally-friendly approach due to the degradation of target pollutants and possesses many advantages such as high selectivity, low cost and easy-to-fabrication
Template and target information:   bisphenol A; BPA; tetrabromobisphenol A; TBBPA; tetrachlorobisphenol A; TCBPA
Author-assigned keywords: Molecularly imprinted polymers; Metal-organic frameworks; Photocatalytic activity; Paper-based analytical device; fluorescent detection




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website