Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Hatamluyi,B.  Rezayi,M.  Beheshti,H.R.  Boroushaki,M.T.    
Article title: Ultra-sensitive molecularly imprinted electrochemical sensor for patulin detection based on a novel assembling strategy using Au@Cu-MOF/N-GQDs
Publication date: 2020
Journal : Sensors and Actuators B: Chemical
Volume: 318
Article number: 128219
DOI: 10.1016/j.snb.2020.128219
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0925400520305645

Abstract: This study introduces an innovative procedure for the development of a molecularly imprinted electrochemical sensor for ultra-sensitive and selective detection of patulin. Firstly, the surface of a glassy carbon electrode (GCE) was decorated by nitrogen doped graphene quantum dots (N-GQDs) and AuNPs-functionalized Cu-metal organic framework (Au@Cu-MOF) and then a layer of molecularly imprinted polymer (MIP) was grown on Au@Cu-MOF/N-GQDs/GCE by electropolymerization. Electrochemical techniques were used to characterize and study the electrochemical behavior of the MIP/Au@Cu-MOF/N-GQDs/GCE, which exhibited a stable reference peak of Au@Cu-MOF at -0.11 V after elution of patulin molecules. This peak current density decreased with rebinding of patulin molecules therefore it was considered as indicator signal. The designed MIP sensor presented a wide linear range from 0.001 to 70.0 ng mL-1, and a low detection limit (0.0007 ng mL-1). This newly developed method based on the synergistic effects of N-GQDs and Au@Cu-MOF combined with MIP technique offered outstanding selectivity, sensitivity, stability, and reproducibility. The good accuracy (recovery%, 97.6-99.4) and high precision (RSD%, 1.23-4.61) of this sensing system for analysis of apple juices proved the high potential of it for rapid and low cost determination of patulin compared to chromatographic methods
Template and target information:   patulin
Author-assigned keywords: patulin; molecularly imprinted polymer; Metal-organic framework; Nitrogen doped graphene quantum dots; Electrochemical sensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website