Article title: Electrochemically initiated co-polymerization of monomers of different oxidation potentials for molecular imprinting of electroactive analyte
Publication date: 2019
Journal : Sensors and Actuators B: Chemical
Volume: 298
Article number: 126884
DOI: 10.1016/j.snb.2019.126884
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0925400519310834

Abstract: Herein, we report an electrochemically initiated co-polymerization of two electroactive monomers of different oxidation potentials. The molar ratio of low oxidation potential monomer in the solution for electropolymerization was optimized to find condition suitable for co-polymerization of high-oxidation potential monomer effectively at lower oxidation potential. The XPS analysis confirmed successful co-polymerization. This co-polymerization condition was further used in imprinting of melatonin, an electroactive compound. Entrapment of melatonin in the polymer matrix was confirmed by measuring electroactivity of melatonin in the 0.1 M KCl-HCl solution (pH 1.6). This MIP based electrochemical sensor determined melatonin in the linear dynamic concentration range 10-80 μM. Detectability of proposed chemosensor was 0.14 μM (S/N = 3). The mean RSD for the concentration range studied was ~20%. Selectivity of the chemosensor was satisfactory towards common structural analogues and biomolecules. Furthermore, the chemosensor was successfully used to determine melatonin in real samples. The sensitivity in the presence of matrix components and that for the KCl-HCl solution were quite similar. The results obtained indicate the suitability of the devised chemosensor for practical applications
Template and target information:   melatonin
Author-assigned keywords: Electroactive analyte; molecular imprinting; co-polymerization; Electrochemical sensor; Melatonin; differential pulse voltammetry




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website