Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Alizadeh,T.  Nayeri,S.    
Article title: An enzyme-free sensing platform based on molecularly imprinted polymer/MWCNT composite for sub-micromolar-level determination of pyruvic acid as a cancer biomarker
Publication date: 2020
Journal : Analytical and Bioanalytical Chemistry
Volume: 412
Issue: (3)
Page numbers: (657-667)
DOI: 10.1007/s00216-019-02273-4

Abstract: Pyruvic acid (PA) has been demonstrated to be an important cancer biomarker. Herein, carbon/carbon nanotube paste electrode was modified with the newly synthesized PA-imprinted polymer (MIP) and used as an enzyme-free sensor for PA assay. Methacrylic acid and ethylene glycol dimethacrylate were copolymerized in the presence of PA to prepare PA-IP. The MIP was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. To analyze PA by the MIP/CNT-CP electrode, the electrode was incubated in the PA solution for a constant time and then, the anodic differential pulse voltammetry signal was recorded. Both extraction and electrochemical determination solutions were the same, making the procedure simple and fast. Presence of the CNT in the MIP electrode led to a great enhancement in the PA signal. The MIP material not only pre-concentrated PA at the electrode surface but also increased the electron-exchange rate. This was confirmed by electrochemical impedance spectroscopy. The effects of electrode composition, extraction condition, and voltammetry parameters on the sensing efficiency were optimized. Dynamic linear range, detection limit, and RSD of the sensor were estimated to be 0.1-200 μM, 0.048 μM (S/N), and 3.6% (n = 3), respectively. The utility of the method was confirmed by appropriate analysis results obtained for the determination of PA in the plasma and urine samples
Template and target information:   pyruvic acid; PA
Author-assigned keywords: molecular imprinting polymer; Carbon nanotube; Pyruvic acid; Carbon paste; differential pulse voltammetry




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website