Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Parnianchi,F.  Kashanian,S.  Nazari,M.  Santoro,C.  Bollella,P.  Varmira,K.    
Article title: Highly selective and sensitive molecularly imprinting electrochemical sensing platform for bilirubin detection in saliva
Publication date: 2021
Journal : Microchemical Journal
Volume: 168
Article number: 106367
DOI: 10.1016/j.microc.2021.106367
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X21004513

Abstract: In this study, molecular imprinting polymer (MIP) was used to develop selective active sites for low-cost and easy-to-build bilirubin (BR) detection because BR is known as an indicator of liver function. When the liver does not excrete BR properly, it causes jaundice, which is associated with liver diseases, especially in infants. High levels of BR can cause serious brain and spinal cord damage. Therefore, the identification and measurement of BR is important. In this study, the amount of BR in saliva was determined for the first time, which is non-invasive and cost-effective. Multi-walled carbon nanotubes (MWCNTs) were used for electrode modification before electropolymerization and MIP electrode preparation. o-phenylenediamine (OPD) was electropolymerized in the presence and absence of BR. The modified electrodes were characterized using different techniques. The electrochemical sensor exhibited an excellent selectivity and sensitivity, notably 1.05 μA fM-1. Moreover, the proposed sensor showed a wide linear range (12.08 fM to 91.81 fM) with a low detection limit of 7.80 fM. Moreover, the MIP electrode demonstrated acceptable operational stability (5% of signal loss over 10 days). After a deep characterization of the sensing platform, the MIP-modified electrode was utilized for the selective detection of BR in the saliva and serum of infants
Template and target information:   bilirubin; RB
Author-assigned keywords: molecular imprinting polymer; Bilirubin; Electrochemical sensor; Saliva; o-phenylenediamine




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website