Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Afzali,M.  Mostafavi,A.  Afzali,Z.  Shamspur,T.    
Article title: Designing a rapid and selective electrochemical nanosensor based on molecularly imprinted polymer on the Fe3O4/MoS2/glassy carbon electrode for detection of immunomodulatory drug pomalidomide
Publication date: 2021
Journal : Microchemical Journal
Volume: 164
Article number: 106039
DOI: 10.1016/j.microc.2021.106039
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X21001247

Abstract: Despite the importance and necessity of pomalidomide determination due to the dual activity of it in vitroandin vivo, electrochemical methods have not been applied for this purpose, so far. We have developed a sensor based on molecular imprinted polymer/iron oxide nanoparticles/molybdenum disulfide nanosheets/glassy carbon electrode (MIP/Fe3O4/MoS2/GCE) to electrochemical determine pomalidomide. Fe3O4/MoS2 nanocomposite was obtained through hydrothermal method and characterized by energy dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), X-ray diffraction (XRD) and transmission electron microscopy (TEM) techniques. Afterwards, the nanocomposite was casted on the GCE to improve the response signal. Then, MIP was fixed on the Fe3O4/MoS2/GCE surface using electrochemical polymerization process to selectively recognize pomalidomide. The electrochemical measurements was studied by square wave voltammetry (SWV) as a rapid and sensitive technique for determination of pomalidomide. Under the optimum conditions, the calibration curve linear range was found to be 1.0 nM-200.0 nM. The limit of quantification and detection were calculated 1.0 nM and 0.33 nM, respectively. Furthermore, the prepared sensor was successfully employed to quantify pomalidomide in health volunteer plasma and pharmaceutical samples with satisfy results
Template and target information:   pomalidomide
Author-assigned keywords: Pomalidomide; molecularly imprinted polymer; FeO; MoS nanocomposite; Glassy carbon electrode; Square wave voltammetry




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website