Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   de Cássia Mendonça,J.  da Rocha,L.R.  Capelari,T.B.  Prete,M.C.  Angelis,P.N.  Segatelli,M.G.  Tarley,C.R.T.    
Article title: Design and performance of novel molecularly imprinted biomimetic adsorbent for preconcentration of prostate cancer biomarker coupled to electrochemical determination by using multi-walled carbon nanotubes/Nafion®/Ni(OH)2-modified screen-printed electrode
Publication date: 2020
Journal : Journal of Electroanalytical Chemistry
Volume: 878
Article number: 114582
DOI: 10.1016/j.jelechem.2020.114582
Alternative URL: https://www.sciencedirect.com/science/article/pii/S1572665720308109

Abstract: The present paper describes the development of a new electroanalytical method for prostate cancer biomarker (sarcosine) by coupling molecularly imprinted solid-phase extraction (MISPE) with electrochemical determination at a MWCNT/Nafion-«/Ni(OH)2-modified screen-printed electrode using a flow injection analysis (FIA) system. The synthesized MIP prepared by using dual functional monomers 2-acrylamido-2-methyl-1-propanesulfonic acid and 4-vinylpyridine was characterized by Fourier Transform Infrared (FT-IR) spectroscopy, Scanning Electron Microscopy (SEM) and nitrogen adsorption/desorption measurements. The optimized pH for adsorption of sarcosine was 5.0 and the elution was completed with MeOH:HAc (90:10, v/v), whilst the electrochemical determination was performed in FIA system using a sample volume of 121.0 μL, 0.05 mol L-1 NaOH carrier solution, a flow rate of 2.0 mL min-1 and applied potential of 0.7 V vs Ag/AgCl. The proposed method provided enrichment factor of 50.6-fold, linear analytical curve from 3.2 to 25.0 μmol L-1 (R2 = 0.995), and limit of detection of 0.96 μmol L-1. The precision was evaluated in terms of intra (n = 6) and interday (n = 2) for concentrations of 10.0, 15.0, and 20.0 μmol L-1, giving rise to low percentages of relative standard deviations (RSD %), ranging from 2.2 to 4.3%. A highly improved response for sarcosine using MIP when compared to NIP (non-imprinted polymer) was obtained. The method also exhibited higher selectivity toward sarcosine compared to glycine, alanine, proline, and urea. Analysis of synthetic urine samples yielded recoveries in the range of 95.0-108.0%, thereby indicating the absence of matrix effect and the feasibility of the method for sarcosine determination
Template and target information:   sarcosine
Author-assigned keywords: Cancer biomarker; amino acid; FIA; MIP




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website