Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Gu,C.T.  Wang,L.  Chen,G.S.  Sun,Z.Z.  Wu,L.X.  Tan,W.Q.  Tian,Y.  Ma,J.P.    
Article title: Ultrasensitive detection of perfluorooctane sulfonate using a mixed-monomer imprinted electrochemical sensor
Publication date: 2026
Journal : Microchemical Journal
Volume: 227
Article number: 118583
DOI: 10.1016/j.microc.2026.118583
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26017856

Abstract: A novel molecularly imprinted electrochemical sensor was constructed for highly sensitive and selective detection of perfluorooctane sulfonate (PFOS). By employing a mixed-monomer strategy of copolymerizing o-phenylenediamine and 3,4-diaminotoluene, the resulting molecularly imprinted polymers membrane provided additional methyl and amino groups that facilitated weak van der Waals force with PFOS, significantly enhancing recognition and enrichment. Under optimized conditions, the MIP-P(oPD/3,4DAT)/GCE sensor exhibited a wide linear range of 0.072–20 nM, a high sensitivity of 0.102 μA/nM, and a low detection limit (LOD) of 0.024 nM. Recoveries of 95.6%–103.4% were achieved in the analysis of spiked real water samples. This mixed-monomer strategy effectively overcomes the recognition limitations associated with traditional single-monomer MIPs, providing additional binding sites and significantly enhancing the overall detection performance for PFOS. It also exhibited excellent anti-interference ability, good reproducibility, and long-term stability. The practicality of the sensor was confirmed through successful application in detecting PFOS in environmental water samples and consumer products, with satisfactory recovery rates. This mixed-monomer imprinting strategy offers a reliable and effective platform for monitoring trace PFOS in complex matrices.
Template and target information:   perfluorooctane sulfonate; PFOS
Author-assigned keywords: Mixed-monomer; Molecularly imprinted polymers; Sensor; Ultrasensitive detection; Perfluorooctane sulfonate




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website