Abstract: The present study describes a novel approach for designing a highly sensitive and selective electrochemical sensor for the detection of SARS-CoV-2 in saliva samples by sensing the S-protein, using an electrochemically controlled preconcentration. The sensor is based on electropolymerized molecularly imprinted polypyrrole (PPy) onto a screen-printed carbon electrode (MIP/PPy). The morphology of the MIP/PPy sensor was evaluated by SEM and AFM. The selectivity of the MIP/PPy compared to NIP/PPy was assessed by rebinding S-protein, followed by the monitoring of the redox probe ([Fe(CN)6]3−/4−). A substantial decrease in the anodic peak current of the redox probe was noticed when using the MIP/PPy. The detectability of the sensor was greatly improved (c.a 1,000,000 fold) by using controlled electrochemical preconcentration of S-protein at +0.6 V for 1.0 min in the rebinding process. Under this condition, a low limit of detection of 6.8fg mL−1 and an analytical curve in the range of 50.0–125.0 fg mL−1 (R2 = 0.996) was obtained. The reproducibility for 10 authentic sensors was highly satisfactory with a relative standard deviation (%,RSD) of 2.8 %. Upon preparation, the sensor can be stored for up to 14 days under refrigeration, with a response efficiency greater than 85 %. The MIP/PPy exhibited high selectivity toward S-protein compared to antitrypsin, human serum albumin (HAS), transferrin, HIgG, and lysozyme. The sensor was applied for detecting SARS-CoV-2 virus through S-protein in infected patients’ saliva samples and validated by RT-PCR. In addition, the satisfactory recovery (91 to 103 %) in S-protein spiked negative samples attested to the free-interference analysis.
Template and target information:   virus; SARS-CoV-2; protein; spike protein; S-protein
Author-assigned keywords: COVID-19; Spike glycoprotein; Antigen test; Viruses diagnosis; MIP-sensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website