Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Hang,Q.  Yin,H.W.  Yuan,Y.  Jiang,X.  Zhao,L.S.  Xiong,Z.L.    
Article title: Magnetic molecularly imprinted polymers based on eco-friendly deep eutectic solvent for recognition and extraction of three glucocorticoids in lotion
Publication date: 2022
Journal : Microchemical Journal
Volume: 183
Article number: 107975
DOI: 10.1016/j.microc.2022.107975
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X22008037

Abstract: In this study, a magnetic dispersive micro-solid phase extraction (MD-μ-SPE) pretreatment method assisted by deep eutectic solvent-magnetic molecularly imprinted polymers (DES-MMIPs) was established in combination with UHPLC-UV analysis method for extraction and determination of Hydrocortisone (HC), cortisone (COR) and dexamethasone (DEX) in lotion. The prepared DES-MMIPs were characterized by FT-IR, SEM and VSM, showing the successful synthesis DES-MMIPs. Then, a series of adsorption affinity tests indicated the prepared material had excellent adsorption capacity, specific recognition performance (IF = 1.33–1.44) and satisfactory reusability (four times). The DES-MMIPs combine the low toxicity of DES, selectivity of MIPs and the convenience of recovery offered by magnetism. Furthermore, the adsorption and desorption conditions were investigated. Under the optimum conditions, the method detection limits (MDLs) of HC, COR and DEX were 0.6, 0.6 and 0.9 ng mL−1, respectively. And the method linear ranges of HC, COR and DEX were 1.8–115.2, 1.8–115.2 and 3.5–224.0 ng mL−1, respectively, which showed a good correlation (r > 0.9997). The extraction recovery ranged from 81.2 % to 96.7 %. Finally, three glucocorticoids were not detected in some lotion samples. Therefore, the established MD-μ-SPE-UHPLC-UV method provides a promising strategy to the selective extraction and determination of three GCs in lotion.
Template and target information:   hydrocortisone; HC; cortisone; COR; dexamethasone; DEX; glucocorticoids
Author-assigned keywords: Magnetic molecularly imprinted polymers; Deep eutectic solvent; Magnetic dispersive micro-solid phase extraction; Glucocorticoids; Specific recognition




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website