Reference Type: Journal
Authors:   Sun,Z.  Wang,D.H  Wang,N.  Jin,J.  Zhang,Y.M.    
Article title: Biomimetic MOF/MIPs carbohydrate microfluidic paper chip: A versatile sialic acid detection platform from point-of-care screening to food rapid analysis
Publication date: 2026
Journal : Talanta
Volume: 303
Article number: 129490
DOI: 10.1016/j.talanta.2026.129490
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0039914026001451

Abstract: The development of new technologies for at-home self-testing holds promising potential for chronic disease management and monitoring. Recently, microfluidic paper-based analytical devices (μPADs) have demonstrated versatile capabilities for point-of-care testing (POCT). Sialic acid (SA), closely linked to the modification of glycoproteins in vivo, serves as an important biomarker for home-based self-testing. In this study, a novel paper-based microfluidic biomimetic chip (FP@Zr-BA@MIP) was successfully developed using boronate affinity surface imprinting technology. This chip exhibited a high adsorption capacity (Qe = 352.83 mg g−1), good selectivity (imprinting factor, IF = 3.67), rapid detection efficiency (within 30 min), and excellent anti-interference capability against sialic acid. Additionally, a visual sensing system was integrated into the platform, enabling rapid, visual, and quantitative analysis of SA. A linear range of 0.1–25 mg L−1 was achieved, with the limit of detection (LOD) and limit of quantitation (LOQ) as low as 0.066 mg L−1 and 0.21 mg L−1, respectively. The synergistic combination of the simple operational features inherent to paper-based microfluidics and the intuitive readout advantage of visual sensing significantly enhanced the simplicity and overall efficiency of the detection process. This design offers a novel approach for realizing a POCT platform for non-invasive analysis of SA.
Template and target information:   sialic acid; SA
Author-assigned keywords: Boronate affinity; Molecularly imprinted polymers; Non-invasive; Visual detection; Point-of-care testing




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website