Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Stefan-van Staden,R.-I.  Georgescu-State,R.  Gheorghe,D.-C.  Gifu,I.C.    
Article title: A new design for stochastic sensors based on an innovative dual-template molecularly imprinted polymer
Publication date: 2026
Journal : Microchemical Journal
Volume: 228
Article number: 119013
DOI: 10.1016/j.microc.2026.119013
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26022162

Abstract: MIPs are synthetic alternatives of biological molecules due to their long-term chemical and physical stability and low-cost synthesis procedure. Using the technique for MIPs synthesis is a great way to construct shapes as channels/pores that can serve for signal development of stochastic sensors. A dual-template molecularly imprinted polymer (dual-MIP) was used for the design of an innovative stochastic sensor. TNF-α and CRP were chosen as model analytes, as both of them served as prognostic biomarkers for cardiovascular diseases. The sensor was fabricated by electropolymerizing 8-amino-1-naphthol-3,6-disulfonic acid onto a glassy carbon electrode modified with silver nanospheres and γ-cyclodextrin (γ-CD), using both C-reactive protein (CRP) and tumor necrosis factor-α (TNF-α) as template molecules. Complete elution of the templates yielded selective recognition sites within the polymer matrix. The linear working concentration ranges were 5.00 × 10−18–5.00 × 10−8 g mL−1 for TNF-α and 1.00 × 10−18–1.00 × 10−7 g mL−1 for CRP, high sensitivities being recorded for both analytes. Pearson correlation coefficient showed a positive, high correlation between the result obtained using the stochastic sensor and a gold standard method (ELISA) used for the determination of TNF-α and CRP from whole blood. The significance of this study lies in the synergistic combination of dual molecular imprinting with stochastic sensing, enabling real-time, label-free detection in complex biological matrices. Validation of the stochastic sensor as screening tool for whole blood samples was done by screening whole blood samples from confirmed patients with cardiovascular diseases. The test demonstrated the sensors' diagnostic relevance and their potential to be used in point-of-care implementation.
Template and target information:   dual-template; protein; tumor necrosis factor-α; TNF-α; C-reactive protein; CRP
Author-assigned keywords: Dual-template molecularly imprinted polymer; Stochastic sensor; TNF-α; CRP




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website