Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Erol,K.  İlhan,M.  Gökmeşe,F.    
Article title: Ultra-trace detection of antidepressants in hospital wastewater using nanoMIP-based surface plasmon resonance sensors
Publication date: 2026
Journal : Sensors and Actuators B: Chemical
Volume: 457
Article number: 139730
DOI: 10.1016/j.snb.2026.139730
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0925400526003084

Abstract: The environmental dissemination of antidepressants such as fluoxetine (FLU) and carbamazepine (CBZ) is of concern due to their persistence and biological activity in aquatic ecosystems. Here, a nanoMIP-based surface plasmon resonance (SPR) sensor was developed for ultra-trace detection of FLU and CBZ in complex aqueous media. Antidepressant-specific nanoMIPs were synthesized via solid-phase imprinting on functionalized glass beads, affording high imprinting fidelity and uniform nanoparticle morphology. The nanoMIPs were covalently immobilized onto gold SPR chips and characterized by DLS, TEM, AFM, and electrochemical analyses. The sensor showed excellent sensitivity, with detection limits of 3.38 ng·L⁻¹ for FLU and 2.13 ng·L⁻¹ for CBZ. The binding data fitted best to the Langmuir–Freundlich isotherm, indicating a transition from heterogeneous to homogeneous binding behavior. Selectivity coefficients were 8.22 for FLU and 9.51 for CBZ, while values of 3.74–6.02 were obtained for structural analogs, confirming high target specificity and low cross-reactivity. Application to real hospital wastewater yielded recovery rates of 95.7–99.1%, in close agreement with liquid chromatography–tandem mass spectrometry (LC-MS). Overall, the nanoMIP–SPR platform provides a rapid, reliable, and cost-effective tool for monitoring pharmaceutical pollutants and shows strong potential for environmental surveillance and sustainable water quality management.
Template and target information:   fluoxetine; FLU; carbamazepine; CBZ
Author-assigned keywords: Antidepressants; Environmental monitoring; Hospital wastewater; NanoMIP; Surface plasmon resonance




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website