Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Wang,Z.Y.  Sun,X.L.  Xu,Y.L.  Yang,L.X.  Wang,M.H.  Xia,Y.Y.  Wang,Y.  Tang,Y.  Qiao,C.  Lin,Y.    
Article title: Fabrication of fluorescence sensor based on semi-covalent dummy molecularly imprinted silica on silane-modified carbon quantum dot for highly selective and sensitive detection of bisphenol A in spirits
Publication date: 2024
Journal : Colloids and Surfaces A: Physicochemical and Engineering Aspects
Volume: 696
Article number: 134292
DOI: 10.1016/j.colsurfa.2024.134292
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0927775724011531

Abstract: Spirits, a Chinese liquor, is susceptible to bisphenol A (BPA) contamination during production and storage. Therefore, developing an accurate and sensitive method for BPA detection in spirits samples is necessary. In this study, a fluorescence sensor (Si-CQDs@DMIPs) with a low detection limit for BPA was synthesized by combining semi-covalent dummy molecular imprinting and silane-modified carbon quantum dot (Si-CQD) techniques. The structure, morphology, and fluorescence properties of Si-CQDs@DMIPs were investigated using transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), and fluorescence spectroscopy (FS). The principle of the selective recognition and detection of BPA by the prepared Si-CQDs@DMIPs is that the molecular imprinting layer can selectively capture BPA and quench the fluorescence intensity of Si-CQDs, due to the electron transfer from BPA to the Si-CQDs. Under optimal conditions, the fluorescence intensity of Si-CQDs@DMIPs sensor showed a good linear decrease (R2 > 0.99) when BPA concentration was 6–1800 nmol/L, and the detection limit was 0.65 nmol/L (3 σ/S). When applied to spirits samples, Si-CQDs@DMIPs exhibited recovery rates between 81.5% and 93.8% with relative standard deviations (RSDs, n = 5) of 3.0–5.8% (spiked at 50, 200, 500, and 1000 nmol/L). Overall, Si-CQDs@DMIPs enable the highly selective and sensitive direct measurement and rapid screening of BPA in spirits.
Template and target information:   bisphenol A; BPA
Author-assigned keywords: Carbon quantum dot; Dummy template; Semi-covalent imprinting; Fluorescence sensor; Spirits




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website