Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Rokhmat,L.S.K.  Irkham,  R.,Putra Rafli  Z.,Serly  K.,Wulan  W.,Dika Apriliana  A.,  Wyantuti,S.  Maksum,I.P.  Einaga,Y.  Ogata,G.  Hartati,Y.W.    
Article title: Hydrogel molecularly imprinted polymer–based electrochemical sensor on gold-modified screen-printed carbon electrodes for stable and selective HbA1c detection
Publication date: 2026
Journal : Biosensors and Bioelectronics
Volume: 300
Article number: 118466
DOI: 10.1016/j.bios.2026.118466
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0956566326000989

Abstract: Glycated hemoglobin (HbA1c) is a key biomarker for long-term glycemic control and diabetes diagnosis. Common methods such as chromatography and immunoassays are accurate but require costly instrumentation, limiting their use in point-of-care settings. Electrochemical sensors offer a portable and sensitive alternative. This study integrates computational modeling with hydrogel-based molecularly imprinted polymer (MIP) engineering to achieve selective HbA1c recognition. Molecular docking coupled with molecular dynamics simulations guided the rational design, identifying optimal binding sites and confirming the structural stability of the monomer–template complex. A hydrogel MIP sensor was fabricated on a gold-modified screen-printed carbon electrode using 2-acrylamido-2-methyl-1-propanesulfonic acid as the functional monomer and ethylene glycol dimethacrylate as the crosslinker. Successful polymer formation and template removal were confirmed by FTIR and XPS, while SEM verified uniform deposition of gold particles and MIP layers. Electrochemical characterization was performed using K3[Fe(CN)6]as the redox probe. The developed SPCE/Au/MIPs sensor exhibited a wide linear range 10–105 ng/mL and LOD 1.13 ng/mL. A strong imprinting factor (IF 4.96) and high selectivity (98.7 %) confirmed effective molecular recognition, while long-term stability was demonstrated by stable performance over 120 days at room temperature with 94 % signal retention. Real sample measurements showed 95–112 % recovery compared to NGSP-standardized HPLC, with good reproducibility, validating its practical applicability. Overall, hydrogel MIP platform provides a robust, sensitive, and durable approach for HbA1c monitoring, supporting good health and well-being through accessible diabetes diagnostics.
Template and target information:   glycated hemoglobin; HbA1c; protein
Author-assigned keywords: Molecularly imprinted polymers; Glycated hemoglobin; Electrochemical sensors; Screen-printed carbon electrode; Long-term stability; Point-of-care diagnostics




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website