Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Longsompurana,P.  Wolschann,P.  Subannajui,K.  Lieberzeit,P.A.  Poo-arporn,R.P.    
Article title: Cyclodextrin-integrated molecularly imprinted polymer-based QCM sensor for sensitive, label-free detection of Gal3
Publication date: 2025
Journal : Biosensors and Bioelectronics
Volume: 287
Article number: 117712
DOI: 10.1016/j.bios.2025.117712
Alternative URL: https://www.sciencedirect.com/science/article/pii/S095656632500586X

Abstract: The global prevalence of heart failure (HF) poses a significant public health challenge. Elevated serum levels of Galectin-3 (Gal3) are a reliable biomarker for the early detection and monitoring of HF progression. Given the high mortality and morbidity associated with HF, early diagnosis is critical, necessitating a rapid, sensitive, and straightforward method for Gal3 detection. This study presents an innovative, label-free quartz crystal microbalance (QCM) sensor designed for Gal3 detection. The sensor uses hexakis-(6-mercapto-6-deoxy)-β-cyclodextrin (mCD) to facilitate the oriented immobilization of the Gal3 template through self-assembly and employs a molecularly imprinted polymer (MIP) for Gal3-specific detection. The mCD-integrated MIP was synthesized by electropolymerizing poly-aniline-3-carboxylic acid (ANI3C), chosen from 20 candidate polymers via molecular docking. Under optimal conditions, the MIP-based QCM sensor demonstrated an imprinting factor (IF) of 4.71 and an equilibrium dissociation constant (KD) of 2.03 nM. This indicates a stronger binding affinity compared to the non-molecularly imprinted polymer (NIP), which exhibited a KD of 26.75 nM. The sensor exhibits a linear detection range of 1–30 ng/mL, with a limit of detection (LOD) of 1.08 ng/mL (S/N = 3) and a limit of quantification (LOQ) of 3.61 ng/mL (S/N = 10). It demonstrated excellent accuracy and precision with no interference, and successfully detected Gal3 in lipid-free human serum, highlighting its potential for in heart failure diagnostics and monitoring.
Template and target information:   protein; galectin-3; Gal3
Author-assigned keywords: Galectin-3; Heart failure; Hexakis-(6-mercapto-6-deoxy)-β-cyclodextrin; Molecular docking; Molecularly imprinted polymer; Quartz crystal microbalance sensor




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website