Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Dykstra,G.  Vera,V.  Chapa,I.  Rao,S.  Liu,Y.X.    
Article title: Engineering electropolymerized molecularly imprinted polymer films for redox-integrated, reagent-free cortisol detection: The critical role of scan rate
Publication date: 2025
Journal : Biosensors and Bioelectronics
Volume: 286
Article number: 117623
DOI: 10.1016/j.bios.2025.117623
Alternative URL: https://www.sciencedirect.com/science/article/pii/S095656632500497X

Abstract: Electropolymerized molecularly imprinted polymers (eMIPs) represent a versatile platform for electrochemical biosensing, offering tailored specificity, high stability, and cost-effectiveness through direct synthesis on electrodes. This study investigates the fabrication-property-performance relationship of eMIPs for enhanced cortisol biosensing, with a focus on the interplay between scan rate and the number of polymerization cycles during cyclic voltammetry-based electropolymerization. The thickness, density, and morphology of the eMIP films were systematically characterized using electrochemical quartz crystal microbalance (EC-QCM), field-emission scanning electron microscopy (FE-SEM), and profilometry. Lower scan rates (25 mV s−1) produced denser and smoother polymer film compared to higher scan rates (50 mV s−1), highlighting the critical influence of scan rate on polymer properties. The eMIP films fabricated with different parameters were integrated with a Prussian Blue nanoparticles layer on screen-printed carbon electrodes for reagent-free cortisol detection. Square wave voltammetry (SWV) was used to evaluate sensor performance, which demonstrates that lower scan rates (25 mV s−1) combined with increased polymerization cycle counts yielded a denser and thicker film, resulting in enhanced sensitivity and selectivity. The sensor achieved a limit of detection (LOD) of 26 pM for cortisol. These findings provide valuable insights into the critical role of electropolymerization parameters in tailoring film properties (i.e., thickness and density), enhancing eMIP sensor design, and advancing biosensor technology through precise control of electropolymerization parameters.
Template and target information:   cortisol
Author-assigned keywords: Electropolymerization; Molecularly imprinted polymers; Cortisol detection; Electrochemical sensors; Scan rate; Film properties




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website