Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   He,S.  Zhang,P.  Sun,J.  Ji,Y.  Huang,C.S.  Jia,N.Q.    
Article title: Integrating potential-resolved electrochemiluminescence with molecularly imprinting immunoassay for simultaneous detection of dual acute myocardial infarction markers
Publication date: 2022
Journal : Biosensors and Bioelectronics
Volume: 201
Article number: 113962
DOI: 10.1016/j.bios.2022.113962
Alternative URL: https://www.sciencedirect.com/science/article/pii/S095656632200001X

Abstract: A novel potential-resolved molecularly imprinted electrochemical luminescence (ECL) immunosensor has been developed for the first time for the dual sensitive detection of markers of acute myocardial infarction (AMI): cardiac troponin I (cTnI) and myoglobin (Mb). In this work, cost-effective and robust molecularly imprinted polymer (MIP) as biomimetic antibody was used to construct the immunosensors through electropolymerization and elution to form polydopamine (PDA)-MIP modified electrode. In the presence of AMI biomarkers, two ECL probes including Ru(bpy)32+@ MOCs and MoS2 QDs functionalized by cTnI antibody and Mb aptamer could be specifically captured respectively. And two potential distinct ECL signals will be generated in one potential scan. The intensity of ECL reflects the concentrations of cTnI and Mb. The two ECL probes were characterized with field emission scanning electron microscopy, X-ray diffraction, FT-IR spectrum and UV–Vis diffuse reflectance spectroscopy. The prepared sensor exhibited a wide linear range (0.05–104 ng/mL) and a low detection limit (0.0184 ng/mL for cTnI and 0.0492 ng/mL for Mb). Additionally, the MIP-ECL sensor displayed excellent anti-interference, sensitivity and stability to detect cTnI and Mb. Therefore, it will be conducive to accelerate more precise and credible early diagnosis for AMI.
Template and target information:   protein; cardiac troponin I; cTnI; myoglobin; Mb
Author-assigned keywords: Potential resolution; Electrochemiluminescence; Molecularly imprinting; Dual detection; Acute myocardial infarction




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website