Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Sfragano,P.S.  Emanuele,A.  Laschi,S.  Ferraro,G.  Fratini,E.  Palchetti,I.    
Article title: Electrochemical sensing of perfluorooctanoic acid in wastewater: Characterization of a molecularly imprinted polymer-based sensor
Publication date: 2026
Journal : Biosensors and Bioelectronics: X
Volume: 28
Article number: 100726
DOI: 10.1016/j.biosx.2025.100726
Alternative URL: https://www.sciencedirect.com/science/article/pii/S2590137025001530

Abstract: Stricter guidelines are progressively established to control the presence of perfluorooctanoic acid (PFOA) in water bodies due to its toxicity and persistence in the environment. This study focused on the development of an electrochemical sensor based on a molecularly imprinted poly(o-phenylenediamine) film to detect PFOA in aqueous matrices. A comparative evaluation of sensor fabrication and analytical performance was performed on gold (AuE) and glassy carbon (GCE) electrodes. Experimental conditions influencing electropolymerization behavior, template removal, polymer morphology, and PFOA recognition were studied. Characterizations using electrochemical techniques and Raman spectroscopy were correlated with analytical performance. These were assessed in spiked buffer solution, yielding concentration-dependent trends over a wide dynamic range, with detection limits of 23.0 and 20.2 ppt for the AuE and the GCE, respectively, meeting the sensitivity requirements of current EU regulations. Selectivity was evaluated by studying sensor response in the co-presence of potential interferents. The sensor was then tested on real samples collected from a wastewater treatment plant. A minor matrix effect was registered in the filtered effluent, supporting the applicability of the sensor for rapid on-site PFOA screening near regulatory thresholds.
Template and target information:   perfluorooctanoic acid; PFOA
Author-assigned keywords: PFAS; PFOA; Molecularly imprinted polymer; Electrochemical sensor; Wastewater




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website