Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   El Hani,O.  Digua,K.  Amine,A.    
Article title: Elimination of non-specific adsorption in the molecularly imprinted membrane: application for tetracycline detection
Publication date: 2025
Journal : Analytical and Bioanalytical Chemistry
Volume: 417
Issue: (10)
Page numbers: (2155-2168)
DOI: 10.1007/s00216-025-05804-4

Abstract: A vital challenge in using imprinted membranes for selective sensing is their non-specific adsorption (NSA). In this study, a novel, rapid, and green approach of NSA-free molecularly imprinted membrane (MIM) preparation was proposed. Sodium alginate was employed as a functional polymer (to interact with the template) and as a membrane matrix, then cross-linked with calcium before template removal to block the unreacted groups, followed by exposure to phosphate to chelate any remaining sites. Unlike the non-imprinted membrane (NIM), which is prepared similarly to MIM and lacks the template cavities, the MIM demonstrated exceptional imprinting factor (IF) (Q(NIM) ≈ 0 mg/g) compared to the initial IF of around 4 before NSA suppress, and a selectivity factor over 10 times greater than that of existing MIMs in the literature. The NSA-free MIM was used as a ready-to-use sensor for spectro-fluorescence and smartphone-based fluorescence detection of tetracycline (TC), achieving detection limits of 0.005 mg/L and 0.015 mg/L, respectively, which were below the maximal acceptable concentrations of TC in real samples. The detection of TC in milk and honey samples using the NSA-free MIM showed significant recoveries (86–101%) compared to those found by MIM before NSA supress (114–122%). The proposed methodology serves as an inspiration for extending NSA removal strategies to other MIMs based on various anionic polymers, including carboxylate, sulfonate, phosphonate, and phenolate anionic groups.
Template and target information:   tetracycline; TC
Author-assigned keywords: Non-specific adsorption; Molecularly imprinted membrane; Smartphone-based fluorescence; Sodium alginate; Tetracycline detection




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website