Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Frigoli,M.  Lowdon,J.W.  Caldara,M.  Arreguin-Campos,R.  Sewall,J.  Cleij,T.J.  Diliën,H.  Eersels,K.  van Grinsven,B.    
Article title: Thermal Pyocyanin Sensor Based on Molecularly Imprinted Polymers for the Indirect Detection of Pseudomonas aeruginosa
Publication date: 2023
Journal : ACS Sensors
Volume: 8
Issue: (1)
Page numbers: (353-362)
DOI: 10.1021/acssensors.2c02345

Abstract: Pseudomonas aeruginosa is a ubiquitous multi-drug-resistant bacterium, capable of causing serious illnesses and infections. This research focuses on the development of a thermal sensor for the indirect detection of P. aeruginosa infection using molecularly imprinted polymers (MIPs). This was achieved by developing MIPs for the detection of pyocyanin, the main toxin secreted by P. aeruginosa. To this end, phenazine was used as a dummy template, evaluating several polymeric compositions to achieve a selective MIP for pyocyanin recognition. The sensitivity of the synthesized MIPs was investigated by UV–vis analysis, with the best composition having a maximum rebinding capacity of 30 μmol g–1 and an imprinting factor (IF) of 1.59. Subsequently, the MIP particles were immobilized onto planar aluminum chips using an adhesive layer, to perform thermal resistance measurements at clinically relevant concentrations of pyocyanin (1.4–9.8 μM), achieving a limit of detection (LoD) of 0.347 ± 0.027 μM. The selectivity of the sensor was also scrutinized by subjecting the receptor to potential interferents. Furthermore, the rebinding was demonstrated in King’s A medium, highlighting the potential of the sensor for the indirect detection of P. aeruginosa in complex fluids. The research culminates in the demonstration of the MIP-based sensor’s applicability for clinical diagnosis. To achieve this goal, an experiment was performed in which the sensor was exposed to pyocyanin-spiked saliva samples, achieving a limit of detection of 0.569 ± 0.063 μM and demonstrating that this technology is suitable to detect the presence of the toxin even at the very first stage of its production.
Template and target information:   bacteria; Pseudomonas aeruginosa; P. aeruginosa; pyocyanin
Author-assigned keywords: Pseudomonas aeruginosa detection; molecularly imprinted polymer (MIP); infection control; pyocyanin; heat-transfer method (HTM); MIP-based sensor; bacterial analysis




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website