Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Bai,B.Q.  Ding,X.H.  Guo,Y.L.  Zhang,Y.  Zhang,J.H.  Bo,T.  Hu,N.  Yang,Y.K.    
Article title: Fabrication of dual-emission molecularly imprinted fluorescent probe for high-selectivity tetracycline tracing detection utilizing differential discrimination tactic
Publication date: 2026
Journal : Analytica Chimica Acta
Volume: 1421
Article number: 345999
DOI: 10.1016/j.aca.2026.345999
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267026009499

Abstract: Tetracycline (TC) overuse in clinical treatment and livestock breeding leads to persistent residues in animal-origin foods, severely endangering food safety and public health. Conventional chromatographic TC detection approaches suffer from expensive instruments and tedious preprocessing, while single-signal fluorescent probes are vulnerable to environmental disturbance and insufficient anti-interference capacity. Herein, an integrated molecularly imprinted ratiometric fluorescent composite (rCDs&NH2-MIL-53(Al)@MIPs) was constructed via a one-pot sol–gel route for sensitive TC measurement. Blue-luminescent NH2-MIL-53(Al) matrix was in-situ loaded with red-emitting carbon dots (rCDs), followed by coating a molecular template-imprinted silica layer to build dual self-calibration emission signals at 435 nm and 585 nm. Under optimized experimental parameters, the fluorescence ratio F435/F585 displayed a favorable linear response toward TC within 0–400 μM, with an ultralow limit of detection of 2.4 nM. The composite possesses outstanding selectivity, recyclability and long-term stability. A differential calibration strategy based on parallel non-imprinted polymer (NIP) tests was adopted to thoroughly eliminate non-selective interference. Practical quantification in spiked milk samples yielded satisfactory recoveries ranging from 86.36% to 97.94%, verifying its reliability for real food matrix analysis. This study delivers a stable, highly sensitive sensing tool for trace TC quantification and diversifies the preparation approaches of MOF/carbon dot dual-emission imprinted sensors in food safety testing.
Template and target information:   tetracycline; TC
Author-assigned keywords: Tetracycline; Ratiometric fluorescence; Molecularly imprinted polymer; Metal–organic framework; Carbon dots




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website