Mipdatabase live, currently comprising 19188 items



Reference Type: Journal
Authors:   Zhang,R.Y.  Shen,J.L.  Sang,X.S.  Dao,X.Y.  Lu,D.  Kong,L.Q.  Cao,Q.    
Article title: Z-scheme WO3/CdS heterojunction-synergized molecularly imprinted photoelectrochemical sensor for ultrasensitive and highly selective detection of gentamicin
Publication date: 2026
Journal : Analytica Chimica Acta
Volume: 1407
Article number: 345491
DOI: 10.1016/j.aca.2026.345491
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267026004411

Abstract: Background Gentamicin (GEN) residues in food pose notable health hazards, including nephrotoxicity and ototoxicity, so developing trace detection methods with high sensitivity and selectivity is urgently required in the field of food safety. Conventional GEN detection approaches such as chromatography and immunosensing have inherent limitations like high cost or complex operation, and single-semiconductor photoelectrochemical (PEC) sensors face insufficient charge separation issues. This work addresses the critical need for developing a high-performance PEC sensing platform that combines superior photoelectric conversion capability with specific molecular recognition. Results A Z-scheme WO3/CdS heterojunction with excellent PEC properties was utilized to develop a novel molecularly imprinted photoelectrochemical sensor (MIP-PECS) for ultrasensitive and highly selective detection of GEN. The bandgap-matched Z-scheme heterojunction serves as a crucial strategy for high-efficiency photoelectrodes. Its built-in electric field (BEF) effectively enhances directional charge separation and significantly suppresses photogenerated carrier recombination relative to single-semiconductor counterparts, while retaining strong redox activities that outperform conventional type-II heterojunctions. A polypyrrole-based molecularly imprinted polymer film (PPy-MIPF) with GEN as template molecule and pyrrole (Py) as functional monomer improves selectivity. The sensor exhibits a low detection limit of 48.4 pmol/L, a wide linear range of 0.0001−100 μmol/L, an imprinting factor (IF) of 9.96, strong anti-interference capability, superior stability and reproducibility, and satisfactory recoveries of 93.2−108.3% in milk and honey samples. Significance This study concludes that the developed MIP-PECS integrates the Z-scheme WO3/CdS heterojunction and PPy-MIPF to achieve excellent balanced PEC performance and selectivity. Combining simple operation and low cost, it overcomes conventional detection method limitations, providing a practical and promising platform for reliable antibiotic detection in food quality monitoring, environmental control and related fields.
Template and target information:   gentamicin; GEN
Author-assigned keywords: Molecularly imprinted polymer film; Photoelectrochemical sensor; Z-Scheme WO/CdS heterojunction; Polypyrrole; Gentamicin




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website