Mipdatabase live, currently comprising 19188 items



Reference Type: Journal
Authors:   Sanli,C.  Isa,A.  Cetinkaya,A.  Gurbuz,H.N.  Sorkhe,Y.  Unal,M.A.  Uzunoglu,A.  Atici,E.B.  Ozkan,S.A.    
Article title: Electrochemical platform based on Ti3C2Tx MXene-supported molecularly imprinted polymers for low-level and selective pomalidomide monitoring
Publication date: 2026
Journal : Analytica Chimica Acta
Volume: 1405
Article number: 345464
DOI: 10.1016/j.aca.2026.345464
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267026004149

Abstract: Background Pomalidomide (POM), a third-generation immunomodulatory drug, is widely used in the therapeutic regimen of multiple myeloma and other hematologic malignancies. Owing to its narrow therapeutic index and substantial interindividual pharmacokinetic variability, accurate quantification of POM in biological matrices is essential to optimize dosing regimens and minimize adverse effects. Conventional analytical systems like HPLC and LC-MS/MS, while highly accurate, can be time-consuming, costly, and technically demanding. Results This study covers the design of a molecularly imprinted polymer (MIP)-based electrochemical sensor incorporating two-dimensional Ti3C2TX MXene nanaolayers (Ti3C2Tx NLs) for sensitive and selective detection and quantification of POM. The sensor's performance was enhanced by the integration of Ti3C2Tx NLs, followed by modifying a GCE via electropolymerization of its surface with 3-thienylboronic acid (3-TBA) as the functional monomer and aniline (ANI) as a co-monomer. Critical parameters, including the template: monomer ratio, the number of polymerization cycles, and the rebinding time, were systematically optimized. EIS, CV, and SEM analyses were used to confirm the formation of selective recognition cavities and the sensor's electrochemical functionality. The developed MIP sensor exhibited excellent linearity across a concentration range of 1.75 × 10−13 M to 1.00 × 10−12 M. It demonstrated outstanding selectivity for POM, even in the presence of structurally similar analogues, co-administered drugs, common biomolecules, and frequently encountered inorganic ions. Significance and novelty Overall, this highly sensitive, selective, and cost-effective MIP-based sensor, which demonstrates excellent stability and performance even in complex matrices, provides a robust, practical analytical tool for routine therapeutic drug monitoring of POM in clinical settings. Moreover, the sensor's straightforward fabrication, low operational cost, and reproducible analytical behavior make it a promising alternative to conventional methods, ultimately contributing to more efficient, accessible, and patient-centered therapeutic monitoring platforms.
Template and target information:   pomalidomide; POM
Author-assigned keywords: Pomalidomide; Drug analysis; Molecularly imprinted polymers; MXene nanomaterials; Electrochemical sensors




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website