Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zhou,H.  Zang,X.F.  Cui,B.  Shen,Y.Z.  Tao,H.T.  Fang,Y.S.    
Article title: Molecularly imprinted multifunctional polymer-modified single-atom-homojunctions for sensitive photoelectrochemical Escherichia coli O157:H7 sensing
Publication date: 2025
Journal : Analytica Chimica Acta
Volume: 1368
Article number: 344339
DOI: 10.1016/j.aca.2025.344339
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0003267025007330

Abstract: Background Foodborne illnesses induced by foodborne pathogenic bacteria pose a tremendous risk to human health and result in massive economic losses. Therefore, the development of rapid detection methods for foodborne pathogenic bacteria is one of the major measures to safeguard food safety. Molecularly imprinted polymers (MIPs)-based photoelectrochemical (PEC) sensors have emerged as an attractive method for the determination of pathogenic bacteria in environmental surveillance. However, the MIPs films in developed PEC sensors are typically non-photoreactive polymers with single functional monomer, causing low recognition performance. Results Here, we designed a novel PEC sensor based on MIPs-modified single-atom-homojunctions (PHI–Cd) for sensitive quantitative detection of Escherichia coli O157:H7 (E. coli O157:H7). Studies have revealed that MIPs prepared with two functional monomers, 1,4-Di (2-thienyl)-1,4-butanedione and piracetam, possess the dual functions of specific recognition and sensitization. The built-in electric field formed inside the PHI–Cd heterojunction can effectively promote the electron-hole pair separation process. Moreover, PHI–Cd exhibited excellent peroxidase-like activity, which effectively catalyzed the production of O2 from H2O2. After the addition of H2O2 to the reaction solution, the production of O2 provided a large number of electron acceptors for the reaction, serving as a signal amplifier. The prepared MIPs-PEC sensor can quantitatively monitor E. coli O157:H7 from 10.0 to 108 CFU/mL, with a LOD of 3.0 CFU/mL. Notably, the non-covalent interaction mode and binding energy between the functional monomer and the E. coli O157:H7 phospholipid bilayer was acknowledged by molecular docking studies. Significance On this basis, this research opens up a wider range of possibilities to analyze the binding sites of template and functional monomers as well as the mechanism of their interactions in the MIPs-PEC sensor, which provided new insights for efficient monitoring of foodborne pathogens to safeguard environmental health and food safety.
Template and target information:   bacteria; Escherichia coli O157:H7; E. coli O157:H7
Author-assigned keywords: Single-atom-homojunctions; O157:H7; Multifunctional polymer films; Peroxidase-like activity; Molecular docking




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website