Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Nguyen,V.-T.  Tran,T.-T.  Vo,T.-K.  Tran,T.T.T.  Trung,H.K.    
Article title: Molecularly Imprinted Polymer‒Solid-Phase Extraction Coupled With High-Performance Liquid Chromatography-Ultraviolet Detection for Selective Determination of Ketoconazole in Cosmetic Shampoo
Publication date: 2026
Journal : Journal of Separation Science
Volume: 49
Issue: (2)
Article number: e70375
DOI: 10.1002/jssc.70375

Abstract: A molecularly imprinted polymer (MIP) was successfully synthesized through precipitation polymerization for the purpose of selectively extracting ketoconazole (KCZ) from cosmetic shampoo matrices. The polymerization process employed methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, azobisisobutyronitrile as the initiator, and KCZ as the template within an acetonitrile/acetic acid (9:1, v/v) solvent system. Conditions for synthesis were optimized to enhance efficiency. Material characterization, conducted via Fourier-transform infrared spectroscopy, scanning electron microscopy, and Brunauer-Emmett-Teller analysis, confirmed the successful formation of the polymer. The MIP demonstrated a maximum adsorption capacity of 1.90 mg/g and a recovery rate of 94.98%, which were significantly higher compared to those of the non-imprinted polymer (0.47 mg/g and 39.67%, respectively). The material exhibited high selectivity for KCZ over structurally similar compounds. A high-performance liquid chromatography method with ultraviolet detection was developed and validated utilizing the synthesized MIP as a selective sorbent. The method displayed excellent linearity over a concentration range of 0.05-500 µg/mL, with a limit of detection of 0.193 µg/g, and a limit of quantification of 0.643 µg/g. These parameters indicate approximately a tenfold enhancement in sensitivity relative to previously reported ultrasound-assisted extraction methods. The method demonstrated excellent precision (relative standard deviation ≤ 6.06%) and high recovery rates (80.41%-98.86%) in real samples. Consequently, this study establishes a cost-effective, selective, and highly efficient approach for the determination of trace levels of KCZ in cosmetic products.
Template and target information:   ketoconazole; KCZ
Author-assigned keywords: matrix cleanup; method validation; molecular recognition; sample preparation; selective extraction




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website