Mipdatabase live, currently comprising 19188 items



Reference Type: Journal
Authors:   Heram,A.Y.  Mengesha,E.T.  Mengesha,A.T.  Bezu,Z.u  Bogale,Y.  Bedada,E.T.  Megerssa,T.T.    
Article title: E. coli Imprinted CdS/ZnO/Ag2CO3 nanocomposites for rapid, sensitive and selective electrochemical E. Coli sensing
Publication date: 2026
Journal : Electrochimica Acta
Volume: 554
Article number: 148335
DOI: 10.1016/j.electacta.2026.148335
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0013468626002288

Abstract: In this work, E. coli imprinted CdS/ZnO/Ag2CO3 nanocomposite was synthesized. The crystal structure, surface area, surface structure, and optoelectronic properties of the as-synthesized materials (ZnO, CdS/ZnO and CdS/ZnO/Ag2CO3) were investigated using XRD, BET, SEM, FTIR, PL and UV-Vis’s instruments. Morphology of templated and non-templated CdS/ZnO/Ag2CO3 nanocomposites were examined by optical Microscope. CV and EIS were used to characterize the electrochemical characteristics of nanomaterial-modified carbon paste electrodes in the presence of 5 mM K3Fe(CN)6 in a 0.1 M KCl aqueous solution. The voltammogram demonstrated that the templated-CdS/ZnO/Ag2CO3 nanocomposite had the highest electrochemical responses as compared to other modified electrodes. The EIS result was likewise comparable with the CV response; CPE modified by the templated system exhibited reduced charge transfer resistance. These behaviors could enhance the sensitivity and responses of the designed sensor for identifying E. coli. To maximize the efficacy of the templated-CdS/ZnO/Ag2CO3/CPE sensor in detecting E. coli, operational conditions were optimized. Using optimized experimental conditions (V=100 mV/s and t = 10 min), the electrode was used to detect E. coli in DI-H2O solutions with varying bacterial concentrations (102 −107 CFU/mL) using cyclic voltammetry (CV). The LOD attained for the templated-CdS/ZnO/Ag2CO3 sensor was 1 × 102 CFU/ml. Besides, the sensor has good stability (88.1%). Moreover, S. aureus and salmonella species were employed as interfering bacteria for the assessment of the specificity of the modified electrode for E. coli. Finally, the results showed that the proposed sensor could be a viable candidate for selective and sensitive E. coli analysis in water samples.
Template and target information:   bacteria; Escherichia coli; E. coli
Author-assigned keywords: Cyclic voltammetry; E. coli; Electrochemical sensor; Imprinted nanocomposites; ZnO; Templated-CdS/ZnO/AgCO




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website