Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Hashmi,Z.  Archana,  Kumar,A.  Solanki,P.R.    
Article title: SnO2-rGO embedded molecularly imprinted polypyrrole based disposable sensing platform utilizing MWCNT for enhanced detection of para-cresyl sulphate
Publication date: 2026
Journal : Electrochimica Acta
Volume: 548
Article number: 147654
DOI: 10.1016/j.electacta.2025.147654
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0013468625020110

Abstract: p-cresyl sulfate (pCS) is a prominent uremic toxin and biomarker for the progression of chronic kidney disease (CKD). This article reports a highly selective and sensitive electrochemical sensor, designed for the early diagnosis of pCS. The sensor is designed with a screen-printed carbon electrode (SPCE) modified by multi-walled carbon nanotube (MWCNT), which improve electrical conductivity as well as helps in fast electron transfer. The detection of pCS was performed using molecularly imprinted polymer (MIP) synthesized with pyrrole as monomer to obtain polypyrrole (Ppy) polymer matrix, and a SnO2-rGO (Stannic oxide-reduced graphene oxide) nanocomposite was incorporated into the Ppy matrix during the process of polymerization. The resulted Ppy-SnO2-rGO-MIP was immobilized onto the MWCNT-modified SPCE surface to produce highly selective binding cavities for pCS recognition. Structural analysis of the nanocomposite and MIP matrix was performed by X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and selected area electron diffraction (SAED). Electrochemical characterization through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) showed a superior sensor performance with sensitivity of 12.81 Ω (ng/mL)⁻¹ cm⁻², wide linear range of 50–3100 ng/mL, and low detection limit of 11.24 ng/mL. Density functional theory (DFT) calculations were performed with B3LYP/3–21 G method, which revealed a favorable interaction between pCS and pyrrole with a binding energy of –12.5 kcal/mol and was supported by theoretical IR spectral shifts. Analysis on real sample by using pCS-spiked urine was also done, which indicated good recovery (102.2–103.2 %) and reproducibility (RSD: 1.5–3.8 %).
Template and target information:   p-cresyl sulfate; PCS
Author-assigned keywords: CNT; Molecularly imprinted polymers; DFT; SnO-rGO; Tertiary nanocomposite; p-cresyl sulphate; Electrochemical impedance spectroscopy




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website