Mipdatabase live, currently comprising 19188 items



Reference Type: Journal
Authors:   Yashwant,  Shukla,A.  Pattanayek,S.K.    
Article title: Molecularly imprinted polymer based electrochemical sensor for the detection of acetylcholine
Publication date: 2025
Journal : Electrochimica Acta
Volume: 541
Article number: 147384
DOI: 10.1016/j.electacta.2025.147384
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0013468625017414

Abstract: The detection and monitoring of Acetylcholine (ACh), a biomarker of Alzheimer’s disease, is of paramount importance in monitoring disease development. We developed an electrochemical sensing method to detect ACh, an electro inactive neurotransmitter. Polyaniline emeraldine salt was synthesised from its monomer in the presence of the template molecules, ACh. The molecularly imprinted polymer (MIP) thus produced was mixed with polyvinyl chloride binder and coated on a glassy carbon electrode (GCE). The MIP coated GCE electrode is used as the working electrode along with Ag/AgCl reference electrode and a platinum counter electrode in an electrochemical cell. The redox couple potassium ferro/ferricyanide (K4/3Fe(CN)6) ions was used to detect the ACh. The presence of benzenoid and quinoid rings in the non-imprinted polymer (NIP) was confirmed by peaks observed in UV–Vis spectroscopy, while the functional groups were identified with Raman spectroscopy. The quartz crystal microbalance technique shows a higher adsorption of ACh molecules in MIP compared to NIP. The cyclic voltammetry shows that the redox couple can detect the ACh in 1X PBS buffer in the concentration range of ACh 10−10 M-10−6 M. The peak current density decreases with increasing ACh concentrations (10−10 M-10−6 M) due to the gradual binding of ACh molecules to MIP. The sensor demonstrated 1.6 times higher sensitivity to ACh on MIP coated GCE electrode than on NIP coated GCE electrode, with a limit of detection of 0.9 nM and a limit of quantification of 2.9 nM for the linear range of ACh concentrations (0.1 nM-10 nM). The MIP sensor exhibited greater specificity for ACh compared to neurotransmitters like L-glutamic acid and γ-aminobutyric acid. The developed MIP sensor is highly effective in detecting ACh in saliva, achieving LOD 0.012 nM and LOQ of 0.040 nM. The actual concentration of ACh found in saliva was 0.95 nM.
Template and target information:   acetylcholine; ACh
Author-assigned keywords: Acetylcholine; Electrochemical detection; MIP; Neurotransmitter; Polyaniline emeraldine salt




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website