Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Rebolledo-Perales,L.E.  Ibarra,I.  Franco Guzmán,M.  Islas,G.  Álvarez Romero,G.A.    
Article title: A novel ion-imprinted polymer based on pyrrole as functional monomer for the voltammetric determination of Hg(II) in water samples
Publication date: 2022
Journal : Electrochimica Acta
Volume: 434
Article number: 141258
DOI: 10.1016/j.electacta.2022.141258
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0013468622014153

Abstract: A novel selective ion-imprinted polymer (IIP) was synthesized, characterized, and used as part of a carbon paste electrode (CPE) for the electrochemical analysis of Hg(II) in real water samples by differential pulse anodic stripping voltammetric (DPASV). Hg-IIP (mercury-ion imprinted polymer) was synthesized using pyrrole for the first time as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a cross-linker agent, and sodium persulfate as initiator. The CPE was modified with IIP (CPE-IIP) with a composite mixture of Hg-IIP (10%), graphite (90%), and 0.08 g of paraffin oil. A notable difference in the Hg(II) Iap (anodic peak current) between a CPE, CPE-IIP and CPE-NIP (non-imprinted polymer) was observed when optimizing the differential pulse anodic stripping voltammetry (DPASV) parameters by a Box-Behnken design. When analyzing a 50 µmol l−1 Hg(II) solution, the optimal conditions (step potential: 0.11 V, amplitude: 0.15 s, modulation time: 0.005 s, and interval time: 0.15 s) allowed an Iap of 144 µA with a %RSD < 10% for the CPE-IIP response, in comparison to the Iap of 1.47 µA obtained with the CPE-NIP, Iap confirming the existence and performance of the recognition cavities in the IIP. The proposed methodology presents a limit of detection (LOD) of 0.02 mg l−1 within a linear range of 0.09 mg l−1 to 20.05 mg l−1. The inter-day and intra-day precision were measured in two concentration levels (1 mg l−1 and 10 mg l−1) with %RSD < 10%. The developed methodology was successfully applied to determine Hg(II) in three spiked samples (10 mg l−1) of natural water sources without acid digestion, obtaining percentage recoveries close to 99.74%, which demonstrates that digestion treatment is not required for this kind of samples.
Template and target information:   mercury ion; Hg(II)
Author-assigned keywords: Modified carbon paste electrode; Hg-ion imprinted polymer; Pyrrole; Differential pulse anodic stripping voltammetry; Box-Behnken design




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website