Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Nguyen,M.-H.  Singla,P.  Dann,A.  Tran,T.H.  Sündermann,J.  Kreienmeyer,M.  Schmitt,H.  Butterbrodt,T.  Schwarz,T.  Schwieger,J.  Scheper,V.  Peeters,M.  Wagner,P.  Warnecke,A.  Kaulen,C.  Körner,J.  Lenarz,T.  Doll,T.    
Article title: Intra-cochlear detection of Interleukin-6 using nanoMIPs embedded in a biodegradable matrix
Publication date: 2026
Journal : Sensing and Bio-Sensing Research
Volume: 51
Article number: 100990
DOI: 10.1016/j.sbsr.2026.100990
Alternative URL: https://www.sciencedirect.com/science/article/pii/S2214180426000401

Abstract: A major challenge in cochlear implant (CI) therapy is postoperative inflammation, which can compromise long-term electrode function. Conventional interleukin-6 (IL-6) detection is challenging due to factors such as its inherent instability. In this study, we present a cost-effective detection strategy using epitope-specific molecularly imprinted polymer nanoparticles (nanoMIPs). These nanoMIPs enable sensitive detection of both IL-6 and its epitope, representing a scalable and economical alternative for inflammation monitoring. NanoMIPs were embedded in a biodegradable chitosan matrix and sprayed onto electrodes. To detect the biomarker, electrochemical impedance spectroscopy was used, a functionality which is already embedded in CI circuits. The sensors enabled reliable detection of IL-6 down to 29 pg/mL, which represents the lowest concentration investigated in this study, with improved sensitivity to the small epitope, as the larger protein causes higher impedance changes due to steric hindrance. Additionally, the sensors enabled concentration-dependent IL-6 detection in human perilymph samples down to 2 pg/mL, with higher signal responses for IL-6 relative to other perilymph components. Comparison with an immunoassay supported analytical accuracy and diagnostic relevance. The sensors were subsequently tested weekly for functionality over four weeks under physiological conditions, with nanoMIP:chitosan ratios of 1:6 and 1:8 being optimal for long-term monitoring. Moreover, the nanoMIPs have a diameter of 56 nm (a parameter that can influence physiological excretion) and cytotoxicity tests demonstrated their biocompatibility. This work presents an epitope-based nanoMIP sensor platform that overcomes economic and biochemical limitations of protein-based biosensors, enabling advanced, real-time self-monitoring CI systems for in-vivo inflammation tracking to reduce implant failure.
Template and target information:   protein; epitope; peptide; interleukin-6; IL-6
Author-assigned keywords: Cochlear implant; Interleukin-6; Nano molecularly imprinted polymers; Chitosan; Electrochemical impedance spectroscopy; Perilymph




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website