Reference Type: Journal
Authors:   Nakamura,M.  Ono,M.  Nakajima,T.  Ito,Y.  Aketo,T.  Haginaka,J.    
Article title: Uniformly sized molecularly imprinted polymer for atropine and its application to the determination of atropine and scopolamine in pharmaceutical preparations containing Scopolia extract
Publication date: 2005
Journal : Journal of Pharmaceutical and Biomedical Analysis
Volume: 37
Issue: (2)
Page numbers: (231-237)
DOI: 10.1016/j.jpba.2004.10.017
Alternative URL: http://www.sciencedirect.com/science/article/B6TGX-4F00Y0T-1/2/b8264f3320d923cf084f2dbfa73b89e3

Abstract: A uniformly sized molecularly imprinted polymer (MIP) for atropine has been prepared. The MIP was prepared using 2-(trifluoromethyl) acrylic acid and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and thermal polymerization method. The selectivity factor, which is defined as the ratio of the retention factors (k) on the molecularly imprinted and non-imprinted polymers, kimprinted/knon-imprinted, was 2.2 for atropine on the MIP. The obtained MIP was applied for the determination of tropane alkaloids (atropine and scopolamine) in a commercial gastrointestinal drug by a column-switching HPLC system, consisting of an MIP material as a pre-column, and a conventional cation-exchange analytical column. An interference peak was observed at the retention time of atropine derived from pre-column. However, since the peak area was less than 0.5% the peak area of atropine of a standard solution under the analytical conditions of this study (0.2 μg of atropine was loaded), this interference was negligible in the determination of atropine. On the other hand, no interference peak was observed at the retention time of scopolamine. Calibration curves of atropine and scopolamine showed good linearity in the range of 0.02-0.9 μg/ml (r = 0.9999) and 0.003-0.09 μg/ml (r = 0.9998), respectively. The mean recoveries of atropine and scopolamine from a placebo pharmaceutical preparation sample were 98.9 and 99.9%, respectively. The intra-day precision (measured by relative standard deviation, R.S.D. (%)) of both ingredients was less than 2.0%. The optimized column-switching system was applied successfully to the determination of atropine and scopolamine in a commercial gastrointestinal drug
Template and target information:   atropine
Author-assigned keywords: molecularly imprinted polymer; Atropine; scopolamine; Scopolia extract; column switching; pharmaceutical analysis




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website