Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Abdallah,A.B.  Amaar,N.M.  Awad,F.S.  El-kholany,M.R.  Mortada,W.I.  Molouk,A.F.S.    
Article title: Single-monomer dual-templated MIP-based electrochemical platform for highly sensitive and selective detection of imeglimin and dapoxetine assisted by metal–organic frameworks and deep eutectic solvents
Publication date: 2026
Journal : Microchemical Journal
Volume: 228
Article number: 119190
DOI: 10.1016/j.microc.2026.119190
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0026265X26023945

Abstract: A novel electrochemical sensor was employed for the simultaneous monitoring of co-administrated Imeglimin (IMG) and Dapoxetine (DAP) drugs, where DAP is directly oxidizable on the electrode surface, whereas IMG is not electroactive. To detect both analytes using a single sensor, a dual-template molecularly imprinted polymer (MIP)-modified electrode was meticulously designed, using IMG and DAP as templates, together with the implementation of a dual-signal sensing strategy. The 1-phenylbut-3-en-1-ol monomer was electropolymerized on a Mil-101 metal–organic framework–modified CPE surface in the presence of both templates, and the sensor selectivity was further enhanced by incorporating deep eutectic solvents (DES). The synthesized monomer, MIP, and DES were characterized by different analytical techniques. The electrochemical performance of the imprinted sensors was examined using CV and EIS. Square wave voltammetry was utilized for monitoring IMG and DAP, using controlled-effect technique, in real samples. The rebinding of templates at the modified CPE surface caused an inhibition effect, leading to a noticeable suppression of the peak signal of the electrochemical probe, and the appearance of a new oxidation peak corresponding to DAP. Insufficient accuracy was observed in DAP detection, depending on its oxidation peak; therefore, it was monitored using a gate-controlled technique. The proposed imprinted sensor detected IMG and DAP individually, demonstrating a broad linear range 0.1–100 μg/mL and 0.02–150 μg/mL for IMG and DAP, and high accuracy with low detection limits of 0.033 and 0.006 μg/mL, respectively. The proposed platform displayed exceptional selectivity along with high stability and reliable repeatability.
Template and target information:   dual template; imeglimin; IMG; dapoxetine; DAP
Author-assigned keywords: Imprinted sensor; Dual template; Imeglimin; Dapoxetine; Metal–organic frameworks; Deep eutectic solvent




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website