Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Zhu,Y.Q.  Xu,Y.X.  Cao,J.Y.  Wang,Y.T.  Hu,X.P.  Song,X.L.    
Article title: Efficient enrichment and distinguishable analysis of microcystin congeners by combining oriented imprinting with array sense strategy
Publication date: 2025
Journal : Journal of Hazardous Materials
Volume: 491
Article number: 137867
DOI: 10.1016/j.jhazmat.2025.137867
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0304389425007812

Abstract: Microcystins (MCs) is one of the most commonly toxic cyclic heptapeptide cyanotoxins with a variety of congeners in aquatic environments. Different MC congeners exhibit different toxicity; however, successful discrimination of MC congeners in complex samples remains challenging. Herein, we combine efficient enrichment of magnetic imprinting and precise discrimination of fluorescence sensor arrays, constructing a new strategy to distinguish MC congeners (MC-LR, MC-RR, and MC-YR). Based on phosphate-guanidine oriented surface imprinting and dummy template imprinting strategy, the prepared magnetic molecularly imprinted materials demonstrated excellent adsorption and selectivity for each MC congeners. The material enriched three MCs simultaneously and eliminated the complex matrix interference in water samples, laying a foundation for array sensing. Finally, a three-unit sensor array was constructed using fluorescent materials interacting with congeners to generate response signals, providing fingerprint patterns to distinguish MCs. Linear discriminant analysis (LDA) processed the fluorescence spectral data, demonstrating 100 % accuracy in differentiation and quantitative discrimination of congeners and their complexes. Combing the advantages of efficient enrichment of magnetic imprinting and precision distinction of fluorescence sensor arrays, the practical application of this method demonstrated good performance in discriminating MCs in real environmental samples.
Template and target information:   dummy template; microcystin LR; MC-LR; microcystin RR; MC-RR; microcystin YR; MC-YR
Author-assigned keywords: Microcystin congeners; Oriented molecularly imprinting; Fluorescence analysis; Array sensing; Magnetic separation




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website