Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Constantinou,A.  Kousi,M.  Kabir,A.  Furton,K.  Kalogiouri,N.P.  Samanidou,V.F.    
Article title: First report of molecularly imprinted polymer-enhanced fabric phase sorptive extraction for highly selective isolation of bisphenol A from environmental waters prior to high-performance liquid chromatography analysis with diode array detection
Publication date: 2026
Journal : Journal of Chromatography A
Volume: 1787
Article number: 467406
DOI: 10.1016/j.chroma.2026.467406
Alternative URL: https://www.sciencedirect.com/science/article/pii/S0021967326007326

Abstract: Bisphenol A (BPA) is among the most extensively utilized and widespreadendocrine-disrupting compounds present in consumer products. In this study, a Fabric Phase Sorptive Extraction (FPSE) membrane functionalized with molecularly imprinted polymers (MIPs), in conjunction with high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD), was employed for the quantification of BPA in environmental water samples. The MIP-FPSE-HPLC-DAD method was systematically optimized by evaluating key parameters influencing analytical performance, including sample matrix pH, duration and ratio of magnetic stirring, type and volume of the extraction solvent, vortex-assisted extraction time, and the addition of salt. The MIP-FPSE membranes exhibited reusability for up to ten extraction cycles. The imprinting factor (IF) was determined to be 6.78 ± 0.19 (n = 3), indicating a high degree of selectivity and binding affinity toward BPA. Method validation was performed to assess linearity, sensitivity, accuracy, and precision. The analytical method demonstrated excellent linearity (R² = 0.9990) over the concentration range of 0.025-5.0 mg/L. Recovery rates ranged from 92.7% to 97.1%, with relative standard deviations (RSDs%) below 6.8%, confirming satisfactory repeatability and precision. The limits of detection (LOD) and quantification (LOQ) were calculated as low as 0.008 mg/L and 0.025 mg/L, respectively, underscoring the method's high sensitivity for trace-level BPA detection.
Template and target information:   bisphenol A; BPA
Author-assigned keywords: Bisphenol A; FPSE; MIPs; Water analysis; HPLC-DAD; MIP-FPSE




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website