Mipdatabase live, currently comprising 19367 items



Reference Type: Journal
Authors:   Esen Coşkun,E.  Demir,M.N.  Ertuğrul Uygun,H.D.    
Article title: Time-Resolved Single-Frequency Chronoimpedance Molecularly Imprinted Urea Sensor
Publication date: 2026
Journal : Sensing and Imaging
Volume: 27
Issue: (1)
Article number: 73
DOI: 10.1007/s11220-026-00767-x

Abstract: Urea is a key clinical biomarker for monitoring renal function and diagnosing kidney-related disorders. However, conventional detection methods are often limited by complex instrumentation, matrix interference, and insufficient sensitivity for real-time applications. In this study, a non-enzymatic molecularly imprinted electrochemical sensor was developed for sensitive and selective urea detection. The sensor is based on a gold nanoparticle-modified screen-printed carbon electrode, onto which a molecularly imprinted polymer was electropolymerized using pyrrole-3-carboxylic acid as the functional monomer, enabling the formation of template-shaped recognition sites complementary to urea. Comprehensive characterization was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS), confirming successful formation of the imprinted layer. Experimental parameters, including monomer-to-template ratio, pH, and desorption conditions, were systematically optimized. The sensor exhibited a limit of detection (LOD) of 3.9 nM, a limit of quantification (LOQ) of 11.9 nM, and a rapid response time of 200 s, as determined by single-frequency chronoimpedance analysis. High selectivity, reproducibility, and storage stability were demonstrated, and accurate urea detection was achieved in artificial serum samples. This cost-effective, miniaturizable, and enzyme-free sensing platform shows strong potential for point-of-care diagnostics and biomedical monitoring.
Template and target information:   urea
Author-assigned keywords: Urea; Detection; Screen-printed electrodes; Molecularly imprinted polymers; Electrochemical sensors




Disclaimer: While every effort has been made to provide accurate information, users are recommended to verify data at the publisher's website

Note: The database is currrently being brought up to date and many articles are therefore not included at this time, please bear this in mind when searching for papers with publication dates from 2022 onwards. Current coverage extends from 2005 to date, for older data, please consult the original mipdatabase website